D8M-D1

Solid State Pressure Sensors D8M 1
Solid State Pressure Sensors
D8M
Solid State Pressure Sensors with
Analog, Pulse or Frequency Outputs
• Compact housing measures 30L x 30W x 12.4H mm.
• Accept 4 mm OD tubing (D8M-A1, -R1); 3 mm OD tubing
for (D8M-D1, -D2), 6 mm OD tubing for D8M-D82.
• Chemical-resistant plastic (PBT) body.
• Metal shield mounted version (D8M-D82) available.
• IP40 enclosure rating for embedded applications.
• Pre-wired and PCB mounting models available.
Ordering Information
Operating pressure
range
Output signal Output frequency Power supply
voltage
Withstand pressure Model
0 to 4.9 kPa
(0 to 0.71 psi)
Analog,
15 to 1247 mV
-- 2.2 ±0.1 VDC 58.8 kPa (8.53 psi) for 3
minutes
D8M-A1
0 to 5.88 kPa
(0 to 0.85 psi)
Pulse count,
1 pulse/9.81 Pa
(1/0.0014 psi)
-- 2.2 to 3.4 VDC with
regulator
58.8 kPa
(8.53 psi) for 3 minutes
D8M-D1
0 to 5.88 kPa
(0 to 0.85 psi)
Pulse count,
1 pulse/9.81 Pa
(1/0.0014 psi)
-- 2.2 to 3.4 VDC with
regulator
58.8 kPa
(8.53 psi) for 3 minutes
D8M-D2
0 to 4.9 kPa
(0 to 0.71 psi)
Pulse count,
1 pulse/9.81 Pa
(1/0.0014 psi)
-- 2.2 to 3.4 VDC with
regulator
19.6 kPa (2.84 psi) for 5
minutes
D8M-D82
0 to 196.13 Pa
(0 to 0.028 psi)
Frequency,
1 kHz/9.81 Pa
(1 kHz/0.0014 psi)
80 to 300 kHz 4.2 to 5.5 VDC with
regulator
3 kPa (0.435 psi) for 10
seconds
D8M-R1
2 Solid State Pressure Sensors D8M
Specifications
Electrical Ratings
Note: 1. Output voltage (mV) = Supply voltage V (2.2) x (2.464 x Pressure (kPa)/9.8 x 1000 + 15)
2. Values measured during and after testing.
Operating Characteristics
Note: With no icing or condensation
Item D8M-A1 D8M-D1 D8M-D2 D8M-D82 D8M-R1
Power supply voltage 2.2 ±0.1 VDC 2.2 to 3.4 VDC with
regulator
2.2 to 3.4 VDC with
regulator
2.2 to 3.4 VDC with
regulator
4.2 to 5.5 VDC with
regulator
Current consumption 2.5 mA max. 25 mA max. 25 µA 100 mA ±5% at 3 VDC 10 mA max.
Load resistance 1 M min. -- -- -- --
Output resistance 500 max. -- -- -- --
Leakage current 1 mA or less 1 mA or less 1 mA or less 1 mA or less 1 mA or less
Output voltage 15 to 1247 mV -- -- -- --
Output pulses -- -- -- -- 80 to 300 kHz
Output resolution (Note 1) 1 pulse/9.81 Pa 1 pulse/9.81 Pa 1 pulse/9.81 Pa 1 kHz/9.81 Pa
Output voltage rate of
change with resistance
load change
1 M or more into 30
k is made within
2.5%
-- -- -- --
Output voltage by input
pressure
0.98 kPa = 261 mV
1.96 kPa = 508 mV
3.73 kPa = 951 mV
4.9 kPa = 1247 mV
(Note 1)
-- -- -- --
Operating characteristics ±62 mV initial -- -- -- --
±37 mV during test
and after
0 kPa = 30 pulses
0.59 kPa = 60 ±32
pulses
1.96 kPa = 200 ±24
pulses
3.73 kPa = 380 ±24
pulses
5.39 kPa = 530 ±82
pulses
(Note 2)
0 kPa = 30 pulses
0.59 kPa = 60 ±32
pulses
1.96 kPa = 200 ±24
pulses
3.73 kPa = 380 ±24
pulses
5.39 kPa = 550 ±82
pulses
(Note 2)
0 kPa = 30 pulses
0.15 kPa = 45 ±30
pulses
2 kPa = 204 ±15
pulses
4 kPa = 438 ±46
pulses
0 Pa =
180 ±100 kHz;
Incremental change
from 0 value:
49.03 Pa =
5 ±0.9 kHz
73.55 Pa =
7.5 ±1.0 kHz
147.10 Pa =
15 ±0.8 kHz
196.13 Pa =
20 ±1.4 kHz
(Note 2)
±62 mV temperature
influence
-- -- -- --
Item D8M-A1 D8M-D1 D8M-D2 D8M-D82 D8M-R1
Pressure type Gauge
Pressure range 0 to 4.9 kPa
(0 to 0.71 psi)
0 to 5.88 kPa
(0 to 0.85 psi)
0 to 5.88 kPa
(0 to 0.85 psi)
0 to 4.9 kPa
(0 to 0.71 psi)
0 to 196.13 Pa
(0 to 0.028 psi)
Withstand pressure 5.88 kPa for 3
minutes
58.8 kPa for 3
minutes
58.8 kPa for 3
minutes
19.6 kPa for 5
minutes
3 kPa for 10
seconds
Repeatability/hystersis ±0.5% FS ±0.5% FS NA ±0.5% FS ±0.5% FS
Non-linearity
characteristics
-- -- -- ±2% FS max. ±2% FS max.
Response time 3.0 ms 2.5 ms (pressure)
18 ms max. (switch)
100 ms (discharge)
3 ms (pressure)
32 ms max. (switch)
250 ms (discharge)
1.5 ms (pressure)
30 ms max. (switch)
45 ms (discharge)
3 seconds max.
Operating temperature
(Note)
-30° to 70°C -30° to 70°C -30° to 70°C -10° to 60°C -20° to 70°C
Storage temperature
(Note)
-40° to 80°C -40° to 80°C -40° to 80°C -20° to 70°C -30° to 80°C
Operating humidity 25 to 95% 25 to 95% 25 to 95% 25 to 95% 25 to 95%
Solid State Pressure Sensors D8M 3
Environmental Characteristics
Operation
Response Timing Charts
D8M-D1, D2, D82
Legend: T1, Pressure measurement time
T2, Response time
T3, Electrical discharge time
D8M-R1
Interface Circuit Diagram
D8M-R1
Application Examples
Compact D8M solid state pressure sensors provide reliable detection
for gas and air inflow for burner controls in water heaters, furnaces
and other gas-fired devices. They can also be used in
gas usage meters.
Item D8M-A1 D8M-D1 D8M-D2 D8M-D82 D8M-R1
Insulation resistance 100 m min., 250 VDC between lead terminals and the base
Dielectric strength 250 VAC, 50/60 Hz for 1 minute between lead terminals and the base 500 VAC, 50/60 Hz for
1 minute between ter-
minals and the base
Degree of protection NA IP40 IP40 IP40 IP40
Pressure port 4 mm OD 3 mm OD 3 mm OD 6 mm OD 4 mm OD
Connection method Solder on PC boards Wiring connector on
top
Wiring connector on
top
Three AWG26 wires,
115 mm long
Wiring connector on
bottom
Weight NA NA NA NA NA
Material PBT (polybutylene terephthalate)
ModelT1T2T3
D8M-D1 2.5 ms min. 18 ms max. 100 ms min.
D8M-D2 3.0 ms min. 32 ms max. 250 ms min.
D8M-D82 1.5 ms min. 30 ms max. 45 ms max.
Response time to 90% of 0.2kPa
Max. 3 seconds (excluding time for pressure change)

D8M-D1

Mfr. #:
Manufacturer:
Description:
SENSOR PRESS PULS OUT 0-5.88KPA
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet