15
Package Tape and Reel Dimensions
Carrier Tape Dimensions
Recommendations for Handling and Storage of
ADJD-S313
Before Opening the MBB (Moisture Barrier Bag)
• The sensor component must be kept sealed in a
MBB (Moisture Barrier Bag) stored at 30°C and
70%RH or less at all times.
• It should also be seal with a moisture absorbent
material (Silica Gel) and an indicator card (Cobalt
Chloride) to indicate the moisture within the bag.
After Opening the MBB (Moisture Barrier Bag)
• The sensor component must be kept at 30°C and
60%RH or less
• The sensor component should have a MET
(Manufacturing Exposure Time) of 24 hours starting
from the time of removal from the MBB to the
soldering oven.
• If unused sensor component remain, it is
recommended to store them back to the MBB.
• If the indicator card has turned from blue to pink or
it has exceeded the recommended MET
(Manufacturing Exposure Time) of 24hrs, baking
treatment should be performed using the following
conditions before continue to IR reflow soldering.
• Baking Treatment: 24 hours at 125°C.
K
o
B
o
SECTION B-B
SECTION A-A
A
o
0.30 ± 0.05
B
B
AA
1.75 ± 0.10
5.50 ± 0.05
12.00 ± 0.10
R 0.50 TYP.
1.55 ± 0.05
8.00 ± 0.10
1.50 (MIN.)
4.00 ± 0.10
SEE NOTE #2
2.00 ± 0.05
SEE NOTE #2
A
o
:
B
o
:
K
o
:
PITCH:
WIDTH:
5.30
5.30
2.20
8.00
12.00
NOTES:
1. A
o
AND B
o
MEASURED AT 0.3 mm ABOVE BASE OF POCKET.
2. 10 PITCHES CUMULATIVE TOLERANCE IS ± 0.2 mm.
3. DIMENSIONS ARE IN MILLIMETERS (mm).