–1–
AECTB35E 201510-T
CAUTIONS FOR USE (Common for BJ, BS and BV types)
Notes for Turquoise Switches (BJ, BS, BV type)
Fastening of the switch body
1) Fasten the switch body onto a smooth surface using the
correct screw as shown in the chart below and tighten it with the
prescribed torque.
The switch case may deform depending on the type of screw
(screw head diameter, etc.), the size of the washer, and the use
or non-use of a washer. Therefore, please confirm the
appropriate torque of actual conditions. Also, it is recommended
that adhesive be applied to lock the screws to prevent loosening
of the screws. When doing so, please be careful not let any
adhesive get inside the switch.
2) Fixed pin type
To secure the switch unit, thermally crimp or press-fit the
mounting pins. If the pins are to be press-fitted, install a guide on
the opposite surface to the mounting pins to prevent them from
slipping out of position and developing play.
3) Be sure to maintain adequate insulating clearance between
each terminal and ground.
4) The positioning of the switch should be such that direct force
is not applied to the pushbutton or actuator in its free position.
The operating force to the pushbutton should only be applied in
a perpendicular direction.
5) The standard value of overtravel used should be within the
range of 70% to 100% of the rated OT value.
6) When soldering the BV type turquoise switch or the
immersion protected type of the BJ and BS type switches, the
sealing material sometimes forms a lump or bulge at the base of
the terminal or lead. Be sure to allow enough space for this
when attaching the switch.
Soldering operations
1) Manual soldering: Perform soldering in less than 3 seconds
with maximum 350°C iron. Care should be taken not to apply
force to the terminals during soldering. We recommend a
soldering iron with temperature adjustment in order to prevent
poor quality soldering.
Please consult us if you intend to use a soldering iron of 60 W or
higher.
2) Terminal portions should not be moved within 1 minute after
soldering.
Selection of the switch
Allow for up to ±20% variation of the specified characteristics
values to compensate for long term operational wear of the
switch in your design.
Cautions regarding use
1) When switching inductive loads (relays, solenoids, buzzers,
etc.), an arc absorbing circuit is recommended to protect the
contacts.
2) If switching of the contact is synchronized with the phase of
the AC power, reduced electrical life or welded contact may
occur. Therefore, test the switch while it is operating under actual
loads for this condition. If found, you may wish to take corrective
action in your design.
3) In the slow or high speed operating condition, the electrical
life might be greatly reduced depending upon the switching load.
Please consult us before use.
4) Using lever type in do not condition, there is the concern that
the flexible part may be impeded and return movement may not
be possible. In this situation take the following precautions:
• Select a product of higher OF or use a leaf type lever.
• Attach a protective cover to the lever.
5) If the leaf lever type switch is excessively pushed (pushed
further than the operational limit position) or switching is done at
high speed or is accompanied by the impact, the lever will break.
Please be careful. Also, be careful with the short roller lever type
ABV (BV) switch as improper return may result from pressing
too much.
Protection from dust, water and corrosive gas
1) The pin button and the space around the body cap Turquoise
switches are sealed with elastic material, the terminal portion is
integrally molded. This prevents dust entry and protects the
switch against corrosive gases. Wireleaded types are
recommended for applications subject to water or oil splash.
However, avoid soaking these immersion protected types in oil
or water, because those types are not of completely oil tight
construction.
2) Switch operation or rapid temperature change while water
droplets are on the switch may cause the water invasion inside
the switch because of breathing action on condensation.
Especially do not use switch in a bath.
If sources of silicon gas are existing in the vicinity of the switch
(silicon rubber, silicon oil, silicon coating, and silicon filler, etc.),
silicon gas (low molecular siloxane, etc.) will be emitted and it
will get into the product due to the permeability of the plastic.
If the switch is used or stored in such an environment, silicon
compound might generate on the contacts, cause the and faulty
contacting. Therefore, please do not use sources that can emit
silicon gas in the vicinity of the switch.
Do not use in areas where flammable or explosive gases from
gasoline and thinner, etc., may be present.
Screws Tightening torque
ABJ (BJ) switches
M1.2 Not more than 0.098N·m
M2.3 Not more than 0.29N·m
M3.0 Not more than 0.29N·m
ABS (BS) switches M2.3 Not more than 0.29N·m
ABV (BV) switches M3.0 Not more than 0.49N·m
Soldering time
ABJ (BJ) switches Within 3 seconds
ABS (BS) switches Within 3 seconds
ABV (BV) switches Within 5 seconds
Notes for Turquoise Switches (BJ, BS, BV type)
–2–
AECTB35E 201510-T
REFERENCE
• Dust protection test
Test conditions: The talcum powder used shall be able to pass
through a square- meshed sieve the nominal wire diameter of 7
μm. The amount of talcum powder to be used is 2 kg per cubic
metre of the test chamber volume. The duration of the test is 8
hours.
No damage observed after the test.
• Waterproof test
Test conditions: Immersion protected IP67 switches ...
Submerge at 1 m below the water surface for 30 minutes.
• Hydrogen sulfide exposure test
Test conditions: Concentration: 3 ppm, Temperature: 40°C
104°F, Humidity: 75% RH
Oil-proof and chemical-proof characteristics
The rubber elastomer swells when exposed to oil and chemicals.
The extent of swelling will vary widely depending on the type and
amount of oil and chemicals.
Check with the actual oil or chemicals used.
In particular, be aware that solvents such as freon, chlorine, and
toluene cannot be used.
Washability [ABJ (BJ) and ABS (BS)]
Do not clean the switch. Doing so can cause problems. Please
contact us if cleaning is necessary.
1Ω
100mΩ
10mΩ
2 4 6 8 10 12 14 16 18 20 22 24
Standard
value 8 hours
Elapsed time (h)
Contact resistance
1000
100
10
2 4 6 8 10 12 14 16 18 20 22 24
Standard value
30 minutes
Elapsed time (h)
Insulation resistance (MΩ)
0 100 200 300 400 500
100Ω
10Ω
1Ω
100mΩ
10mΩ
Elapsed time (h)
Contact resistance
Turquoise switches
Typical products
Dust-protected type
This type of construction prevents dust that is large enough to
have an effect on operation from getting inside the unit. This
construction is stipulated by protective classes against solid
matter in the IEC standards (IEC60529).
The talcum powder used shall be able to pass through a square-
meshed sieve the nominal wire diameter of 7 μm. The amount of
talcum powder to be used is 2 kg per cubic metre of the test
chamber volume. The duration of the test is 8 hours.
No damage observed after the test.
Immersion-protected type
This type of construction prevents any harmful effects even after
the device is left underwater at a depth of 1 m for 30 minutes.
This construction is stipulated by protective classes against
water in the IEC standards (IEC60529).
IEC’s IP Codes
The IEC (International Electrotechnical Commission) has
defined the IP characteristic code that represents the levels of
protection described in IEC standard (IEC60529).
The two numbers that follow the IP code (the characteristics
numbers) indicate the suitability of this protection for all
environmental conditions.
• Level of protection indicated by the 1st Characteristics number
• Level of protection indicated by the 2nd Characteristics number
Note: Details of test conditions are the same as NECA C 0920. Please refer to them.
1st characteristics number
2nd characteristics number
IP
1st
Characteristics number
Protection level (IEC60529/Solid matter)
0 No protection
1 Protected against solid matter larger than 50mm
2 Protected against solid matter larger than 12mm
3 Protected against solid matter larger than 2.5mm
4 Protected against solid matter larger than 1.0mm
5
Dust-protected type
Prevents dust that is large enough to have an effect
on operation from getting inside the unit
6
Dust-resistant type
Prevents dust from getting inside the unit
JIS C0920
2nd
Characteristics
number
Protection level (IEC60529/Liquid matter)
0 No protection
Droplet-protected
type I
1
Protected against water droplets that fall
perpendicular to the unit
Droplet-protected
type II
2
Protected against water droplets that fall
from within 15° of perpendicular to the unit
Rain-protected
type
3
Protected against water droplets that fall
from within 60° of perpendicular to the unit
Splash-protected
type
4
Protected against water that splashes on
the unit from any direction
Spray-protected
type
5
Free from adverse effects even if sprayed
directly with water from any direction
Water-resistant
type
6
Protected against water sprayed directly
on the unit from any direction
Immersion-
protected type
7
Water does not get inside of the unit when
submerged in water according to the
specified conditions
Underwater type 8 Unit can be used underwater

ASQ10330

Mfr. #:
Manufacturer:
Panasonic Industrial Devices
Description:
Basic / Snap Action Switches SPST - NO, Pin Plunger, Wire
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union