TP 04M, TP 06M, TP 06S, TP 07T
7313_en_03 PHOENIX CONTACT 14
9Interface assignment
9.1 Supply voltage
Figure 10 Supply voltage
9.2 USB
Figure 11 Two USB host interfaces
9.3 Ethernet
Figure 12 Ethernet interface
DANGER: Hazardous contact voltage
In electrical systems, hazardous voltages may
occur posing a danger to humans. There is a risk
of electric shock when touching live parts.
Work must only be carried out by qualified
personnel familiar with the required safety
measures.
NOTE:
Provide a separate cable for protective grounding
at the threaded bolt. The cable must have a
minimum cross section of 1.5 mm² and must be
as short as possible.
Pin Designation Function
1 Low-noise ground
2 0 V 0 V supply voltage
3 +24 V DC 24 V DC supply voltage
Use a fine strand cable with a minimum cross
section of 0.75 mm² and a maximum cross
section of 2.5 mm² for the supply voltage.
Pin Designation
1VCC (+5 V DC)
2Data–
3Data+
4GND
Use a fine strand cable with a minimum cross
section of 0.75 mm² and a maximum cross
section of 2.5 mm² for the supply voltage.
For the specification of a suitable cable, please
refer to the "Universal Serial Bus Specification
Rev. 2.0".
The maximum cable length for the cable used is
2.5 m.
Pin Designation Function
1 Tx+ Transmit data, positive polarity
2 Tx- Transmit data, negative polarity
3 Rx+ Receive data, positive polarity
4n.c. Not connected
5n.c. Not connected
6 Rx- Receive data, negative polarity
7n.c. Not connected
8n.c. Not connected
Use a category 5 (CAT 5) twisted pair cable. The
maximum cable length is 100 m.
For additional information, please refer to the
IEEE 802.3 standard.