YV09T60 60A DC-DC POL Converter
5V to 13.8V Input
0.6V to 1.98V Output
Data Sheet
ZD-01724 Rev 3.4, 07-Nov-10 www.power-one.com Page 7 of 14
5.2 Power Dissipation Curves
0
2
4
6
8
10
12
14
0 10 20 30 40 50 60
Load Current, A
Power Dissipation, W
Vin=5V
Vin=9.6V
Vin=12V
Vin=13.8V
Figure 6. Power Dissipation vs. Load. Vout=0.6V
0
2
4
6
8
10
12
14
0 10 20 30 40 50 60
Load Current, A
Power Dissipation, W
Vin=5V
Vin=9.6V
Vin=12V
Vin=13.8V
Figure 7. Power Dissipation vs. Load. Vout=1.2V
0
2
4
6
8
10
12
14
0 10 20 30 40 50 60
Load Current, A
Power Dissipation, W
Vin=5V
Vin=9.6V
Vin=12V
Vin=13.8V
Figure 8. Power Dissipation vs. Load. Vout=1.5V
0
2
4
6
8
10
12
14
0 10 20 30 40 50 60
Load Current, A
Power Dissipation, W
Vin=5V
Vin=9.6V
Vin=12V
Vin=13.8V
Figure 9. Power Dissipation vs. Load. Vout=1.8V
YV09T60 60A DC-DC POL Converter
5V to 13.8V Input
0.6V to 1.98V Output
Data Sheet
ZD-01724 Rev 3.4, 07-Nov-10 www.power-one.com Page 8 of 14
5.3 Turn-On Characteristics
Figure 10. Typical Start-Up Using Remote On/Off
(Vo = 1.2 Vdc, Io=60A). Ch1 Vout, Ch2 On/Off,
Ch3 - Iout
Figure 11. Typical Start-Up with application of Vin
(Vo = 1.2Vdc, Io = 60A). Ch1 Vout, Ch2 Vin, Ch3
- Iout
5.4 Transient Response
Figure 12. Transient Response to Dynamic Load Change
from 0% to 50% of full load (Vin=12V, Vo=1.5V).
Ch1 Vout, Ch3 Iout
YV09T60 60A DC-DC POL Converter
5V to 13.8V Input
0.6V to 1.98V Output
Data Sheet
ZD-01724 Rev 3.4, 07-Nov-10 www.power-one.com Page 9 of 14
5.5 Derating Curves
45
50
55
60
20 30 40 50 60 70
Ambient Temperature, C
Load Current, A
100 LFM (0.5 m/s)
200 LFM (1 m/s)
300 LFM (1.5 m/s)
400 LFM (2 m/s)
500 LFM (2.5 m/s)
Figure 13. Derating Output Current versus Local Ambient
Temperature and Airflow (Vin =12.0V, Vo=0.6V).
45
50
55
60
20 30 40 50 60 70
Ambient Temperature, C
Load Current, A
100 LFM (0.5 m/s)
200 LFM (1 m/s)
300 LFM (1.5 m/s)
400 LFM (2 m/s)
500 LFM (2.5 m/s)
Figure 14. Derating Output Current versus Local Ambient
Temperature and Airflow (Vin=12.0V, Vo=1.2V).
45
50
55
60
20 30 40 50 60 70
Ambient Temperature, C
Load Current, A
100 LFM (0.5 m/s)
200 LFM (1 m/s)
300 LFM (1.5 m/s)
400 LFM (2 m/s)
500 LFM (2.5 m/s)
Figure 15. Derating Output Current versus Local Ambient
Temperature and Airflow (Vin=12.0V, Vo=1.5V).
45
50
55
60
20 30 40 50 60 70
Ambient Temperature, C
Load Current, A
100 LFM (0.5 m/s)
200 LFM (1 m/s)
300 LFM (1.5 m/s)
400 LFM (2 m/s)
500 LFM (2.5 m/s)
Figure 16. Derating Output Current versus Local Ambient
Temperature and Airflow (Vin=12.0V, Vo=1.8V).

YV09T60-0G

Mfr. #:
Manufacturer:
Bel Power Solutions
Description:
Non-Isolated DC/DC Converters 0.6-3.63Vout 60A 5V-13.8VIn