www.fairchildsemi.com 6
74ACQ646 • 74ACTQ646
AC Electrical Characteristics for ACQ
Note 14: Voltage Range 3.3 is 3.3V ± 0.3V.
Voltage Range 5.0 is 5.0V ± 0.5V
Note 15: Skew is defined as the absolute value of the difference between the actual propagation delay for any two outputs within the same packaged device.
The specification applies to any outputs switching in the same direction, either HIGH-to-LOW (t
OSHL
) or LOW-to-HIGH (t
OSLH
). Parameter guaranteed by
design. Not tested.
AC Operating Requirements for ACQ
Note 16: Voltage Range 5.0 is 5.0V ± 0.5V
Voltage Range 3.3 is 3.3V ± 0.3V
V
CC
T
A
= +25°CT
A
= −40°C to +85°C
Symbol Parameter (V)
C
L
= 50 pF C
L
= 50 pF
Units
(Note 14) Min Typ Max Min Max
t
PLH
Propagation Delay 3.3 3.5 9.0 12.0 3.5 13.0
ns
Bus to Bus 5.0 2.5 6.5 9.0 2.5 9.5
t
PHL
Propagation Delay 3.3 3.5 9.0 12.0 3.5 13.0
ns
Bus to Bus 5.0 2.5 6.5 9.0 2.5 9.5
t
PLH
Propagation Delay 3.3 3.5 10.0 13.0 3.5 14.0
ns
Clock to Bus 5.0 2.5 7.0 9.5 2.5 10.5
t
PHL
Propagation Delay 3.3 3.5 10.0 13.0 3.5 14.0
ns
Clock to Bus 5.0 2.5 7.0 9.5 2.5 10.5
t
PLH
Propagation Delay 3.3 3.5 9.5 12.5 3.5 13.5
SBA or SAB to A
n
or B
n
5.0 2.5 6.5 9.0 2.5 10.0 ns
(w/A
n
or B
n
HIGH or LOW)
t
PHL
Propagation Delay 3.3 3.5 9.5 12.5 3.5 13.5
SBA or SAB to A
n
or B
n
5.0 2.5 6.5 9.0 2.5 10.0 ns
(w/A
n
or B
n
HIGH or LOW)
t
PZH
Enable Time 3.3 3.5 10.5 14.5 3.5 15.5
ns
G
to A
n
or B
n
5.0 2.5 8.0 10.5 2.5 11.5
t
PZL
Enable Time 3.3 3.5 10.5 14.5 3.5 15.5
ns
G to A
n
or B
n
5.0 2.5 8.0 10.5 2.5 11.5
t
PHZ
Disable Time 3.3 2.5 8.0 11.0 2.5 12.0
ns
G
to A
n
or B
n
5.0 1.5 5.0 7.5 1.5 8.0
t
PLZ
Disable Time 3.3 2.5 8.0 11.0 2.5 12.0
ns
G
to A
n
or B
n
5.0 1.5 5.0 7.5 1.5 8.0
t
PZH
Enable Time 3.3 4.5 11.0 15.5 4.5 17.0
ns
DIR to A
n
or B
n
5.0 3.0 8.5 11.0 3.0 11.5
t
PZL
Enable Time 3.3 4.5 11.0 15.5 4.5 17.0
ns
DIR to A
n
or B
n
5.0 3.0 8.5 11.0 3.0 11.5
t
PHZ
Disable Time 3.3 1.5 8.0 11.0 1.5 12.0
ns
DIR to A
n
or B
n
5.0 1.0 5.0 7.5 1.0 8.0
t
PLZ
Disable Time 3.3 1.5 8.0 11.0 1.5 12.0
ns
DIR to A
n
or B
n
5.0 1.0 5.0 7.5 1.0 8.0
t
OS
Output to Output Skew (Note 15) 3.3 1.0 1.5 1.5
ns
5.0 0.5 1.0 1.0
Symbol Parameter
V
CC
T
A
= +25°CT
A
= −40°C to +85°C
Units
(Note 16) Typ Guaranteed Minimum
t
S
Setup Time, HIGH or LOW 3.3 3.0 3.0
ns
Bus to Clock 5.0 3.0 3.0
t
H
Hold Time, HIGH or LOW 3.3 1.5 1.5
ns
Bus to Clock 5.0 1.5 1.5
t
W
Clock Pulse Width 3.3 4.0 4.0
ns
HIGH or LOW 5.0 4.0 4.0