www.fairchildsemi.com 6
GTLP18T612
AC Electrical Characteristics
Over recommended range of supply voltage and operating free-air temperature, V
REF
= 1.0V (unless otherwise noted).
C
L
= 30 pF for B Port and C
L
= 50 pF for A Port.
Note 13: All typical values are at V
CC
= 3.3V, and T
A
= 25°C.
Extended Electrical Characteristics
Over recommended ranges of supply voltage and operating free-air temperature V
REF
= 1.0V (unless otherwise noted).
C
L
= 30 pF for B Port and C
L
= 50 pF for A Port.
Note 14: t
OSHL
/t
OSLH
and t
OST
- Output to output skew is defined as the absolute value of the difference between the actual propagation delay for all outputs
within the same packaged device. The specifications are given for specific worst case V
CC
and temperature and apply to any outputs switching in the same
direction either HIGH-to-LOW (t
OSHL
) or LOW-to-HIGH (t
OSLH
) or in opposite directions both HL and LH (t
OST
). This parameter is guaranteed by design and
statistical process distribution. Actual skew values between the GTLP outputs could vary on the backplane due to the loading and impedance seen by the
device.
Note 15: t
PV
- Part to part skew is defined as the absolute value of the difference between the actual propagation delay for all outputs from device to device.
The parameter is specified for a specific worst case V
CC
and temperature. This parameter is guaranteed by design and statistical process distribution. Actual
skew values between the GTLP outputs could vary on the backplane due to the loading and impedance seen by the device.
Note 16: Due to the open drain structure on GTLP outputs t
OST
and t
PV(LH)
in the A-to-B direction are not specified. Skew on these paths is dependent on the
V
TT
and R
T
values on the backplane.
Symbol
From To Min Typ Max Unit
(Input) (Output) (Note 13)
t
PLH
AB2.14.16.3
ns
t
PHL
1.0 2.7 4.4
t
PLH
LEAB B 2.2 4.2 6.3
ns
t
PHL
1.0 2.4 4.2
t
PLH
CLKAB B 2.2 4.4 6.5
ns
t
PHL
1.0 2.5 4.4
t
PLH
OEAB B 2.0 3.8 5.6
ns
t
PHL
1.0 2.6 4.3
t
RISE
Transition Time, B Outputs (20% to 80%) 3.1
ns
t
FALL
Transition Time, B Outputs (20% to 80%) 2.1
t
PLH
BA1.83.85.8
ns
t
PHL
1.8 3.8 5.8
t
PLH
LEBA A 0.3 2.2 4.6
ns
t
PHL
0.4 2.4 4.6
t
PLH
CLKBA A 0.5 2.4 4.6
ns
t
PHL
0.6 2.6 4.6
t
PZH
, t
PZL
OEBA A 0.3 2.7 5.2
ns
t
PHZ
, t
PLZ
0.3 2.5 5.2
Symbol
From To Min Typ Max Unit
(Input) (Output) (Note 13)
t
OSLH
(Note 14) A B 0.8 1.0 ns
t
OSHL
(Note 14) 0.3 0.5 ns
t
PV(HL)
(Note 15)(Note 16) A B 0.8 ns
t
OSLH
(Note 14) CLKAB B 0.9 1.0 ns
t
OSHL
(Note 14) 0.3 0.5 ns
t
PV(HL)
(Note 15)(Note 16) CLKAB B 0.8 ns
t
OSLH
(Note 14) B A 0.7 1.0 ns
t
OSHL
(Note 14) 0.6 1.0 ns
t
OST
(Note 14) B A 0.7 1.1 ns
t
PV
(Note 15) B A 1.5 ns
t
OSLH
(Note 14) CLKAB A 0.5 1.0 ns
t
OSHL
(Note 14) 0.6 1.0 ns
t
OST
(Note 14) CLKAB A 1.1 1.2 ns
t
PV
(Note 15) CLKAB A 1.5 ns