3-WIRE SERIAL E
2
PROM
S-93C76A
Rev.7.0
_00
Seiko Instruments Inc.
4
Block Diagram
Memory array
Data register
Address
decoder
Mode decode logic
Output buffer
VCC
GND
DO
DI
CS
Clock generator
SK
Figure 4
3-WIRE SERIAL E
2
PROM
Rev.7.0
_00
S-93C76A
Seiko Instruments Inc.
5
Instruction Sets
Table 4
Instruction Start Bit Operation Code Address Data
SK input clock 1 2 3 4 5 6 7 8 9 10 11 12 13 14 to 29
READ (Read data) 1 1 0 x A8 A7 A6 A5 A4 A3 A2 A1 A0
D15 to D0
Output
*1
WRITE (Write data)
*2
1 0 1 x A8 A7 A6 A5 A4 A3 A2 A1 A0 D15 to D0 Input
ERASE (Erase data)
*2
1 1 1 x A8 A7 A6 A5 A4 A3 A2 A1 A0
WRAL (Write all)
*2
1 0 0 0 1 x x x x x x x x D15 to D0 Input
ERAL (Erase all)
*2
1 0 0 1 0 x x x x x x x x
EWEN (Write enable)
*2
1 0 0 1 1 x x x x x x x x
EWDS (Write disable) 1 0 0 0 0 x x x x x x x x
*1. When the 16-bit data in the specified address has been output, the data in the next address is output.
*2. WRITE, ERASE, WRAL, ERAL, and EWEN are guaranteed only at V
CC
2.7 V.
Remark x: Don’t care
3-WIRE SERIAL E
2
PROM
S-93C76A
Rev.7.0
_00
Seiko Instruments Inc.
6
Absolute Maximum Ratings
Table 5
Caution The absolute maximum ratings are rated values exceeding which the product could suffer
physical damage. These values must therefore not be exceeded under any conditions.
Recommended Operating Conditions
Table 6
Ta = 40°C to +85°C
Item Symbol Conditions
Min. Max.
Unit
READ, EWDS 1.8 5.5 V
Power supply voltage V
CC
WRITE, ERASE,
WRAL, ERAL, EWEN
2.7 5.5 V
V
CC
= 4.5 V to 5.5 V 2.0 V
CC
V
V
CC
= 2.7 V to 4.5 V 0.8 × V
CC
V
CC
V
High level input voltage V
IH
V
CC
= 1.8 V to 2.7 V 0.8 × V
CC
V
CC
V
V
CC
= 4.5 V to 5.5 V 0.0 0.8 V
V
CC
= 2.7 V to 4.5 V 0.0 0.2 × V
CC
V
Low level input voltage V
IL
V
CC
= 1.8 V to 2.7 V 0.0 0.15 × V
CC
V
Pin Capacitance
Table 7
(Ta = +25°C, f = 1.0 MHz,
V
CC
= 5.0 V)
Item Symbol Conditions Min. Max. Unit
Input Capacitance C
IN
V
IN
= 0 V 8 pF
Output Capacitance C
OUT
V
OUT
= 0 V 10 pF
Endurance
Table 8
Item Symbol Operating Ambient Temperature Min. Max. Unit
Endurance N
W
Ta = 40°C to +85°C 10
6
cycles / word
*1
*1. For each address (Word: 16-bit)
Data Retention
Table 9
Item Symbol Operation Ambient Temperature Min. Max. Unit
Ta = +25°C 100 year
Data retention
Ta = 40°C to +85°C 20 year
Item Symbol Ratings Unit
Power supply voltage V
CC
0.3 to +7.0 V
Input voltage V
IN
0.3 to V
CC
+0.3 V
Output voltage V
OUT
0.3 to V
CC
V
Operating ambient temperature T
opr
40 to +105 °C
Storage temperature T
stg
65 to +150 °C

S-93C76AFM-TF-U

Mfr. #:
Manufacturer:
ABLIC
Description:
EEPROM MICROWIRE EEPROM
Lifecycle: