SL2S5002_SL2S5102 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.4 — 27 August 2012
193134 13 of 35
NXP Semiconductors
SL2S5002; SL2S5102
ICODE SLIX-L
Option 1 (Option flag set) is supported.
9.4.2.9 LOCK DSFID
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
9.4.2.10 GET SYSTEM INFORMATION
As defined in ISO/IEC 15693-3.
The TAG type of the ICODE SLIX-L IC is “03h”.
9.4.3 Custom commands
The manufacturer code of NXP Semiconductors is defined in ISO/IEC 7816-6A1 (Ref. 5).
It has the value “04h”.
For the structure of custom commands please refer to ISO/IEC 15693-3.
If not explicitly specified differently all address modes are supported.
9.4.3.1 GET RANDOM NUMBER
Command code = B2h
The GET RANDOM NUMBER command is required to receive a random number from the
label IC. The passwords that will be transmitted with the SET PASSWORD command
have to be calculated with the password and the random number (see Section 9.4.3.2
SET PASSWORD).
The different passwords are addressed with the password identifier.
Table 7. Request format
SOF Flags GET
RANDOM
NUMBER
IC Mfg
code
UID CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
16 bits -
Table 8. Response format when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 9. Response format when Error_flag NOT set
SOF Flags Random number CRC16 EOF
- 8 bits 16 bits 16 bits -
SL2S5002_SL2S5102 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.4 — 27 August 2012
193134 14 of 35
NXP Semiconductors
SL2S5002; SL2S5102
ICODE SLIX-L
9.4.3.2 SET PASSWORD
Command code = B3h
The SET PASSWORD command enables the different passwords to be transmitted to the
label to access the different protected functionalities of the following commands. The SET
PASSWORD command has to be executed just once for the related passwords if the label
is powered.
Remark: The SET PASSWORD command can only be executed in Addressed or
Selected mode except for the Privacy password. If the Privacy password is transmitted
(see Section 9.4.3.6 “
ENABLE PRIVACY), the timing of the SET PASSWORD command
is write alike.
The XOR password has to be calculated with the password and two times the received
random number from the last GET RANDOM NUMBER command:
XOR_Password[31:0] = Password[31:0] XOR {Random_Number[15:0],
Random_Number[15:0]}.
The different passwords are addressed with the password identifier.
Remark: If the IC receives an invalid password, it will not execute any following command
until a Power-On Reset (POR) (RF reset) is executed.
Table 10. Request format
SOF Flags SET
PASSWORD
IC Mfg
code
UID Password
identifier
XOR
password
CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
8 bits 32 bits 16 bits -
Table 11. Password Identifier
Password identifier Password
04h Privacy
08h Destroy SLIX-L
10h EAS/AFI
Table 12. Response format when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 13. Response format when Error_flag NOT set
SOF Flags CRC16 EOF
- 8 bits 16 bits -
SL2S5002_SL2S5102 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.4 — 27 August 2012
193134 15 of 35
NXP Semiconductors
SL2S5002; SL2S5102
ICODE SLIX-L
9.4.3.3 WRITE PASSWORD
Command code = B4h
The WRITE PASSWORD command enables a new password to be written into the related
memory if the related old password has already been transmitted with a SET PASSWORD
command and the addressed password is not locked (see Section 9.4.3.4 “
LOCK
PASSWORD).
Remark: The WRITE PASSWORD command can only be executed in addressed or
selected mode. The new password takes effect immediately which means that the new
password has to be transmitted with the SET PASSWORD command to access protected
blocks/pages.
The different passwords are addressed with the password identifier.
The timing of the command is write alike.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
Table 14. Request format
SOF Flags WRITE
PASSWORD
IC Mfg
code
UID Password
identifier
Password CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
8 bits 32 bits 16 bits -
Table 15. Password Identifier
Password identifier Password
04h Privacy
08h Destroy SLIX-L
10h EAS/AFI
Table 16. Response format when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 17. Response format when Error_flag NOT set
SOF Flags CRC16 EOF
- 8 bits 16 bits -

SL2S5102FUD,003

Mfr. #:
Manufacturer:
NXP Semiconductors
Description:
RFID Transponders ICODE SLIX-L
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet