1Description
AxiolineE IO-Link/analog converter for connecting
an RTD, rectangularversion
AXL E IOL RTD1 M12 R
© PHOENIX CONTACT
Data sheet
The IO-Link/analog converter is an IO-Link slave that con-
verts analog signals into the IO-Link protocol.
It therefore offers the option of acquiring the signals of ana-
log sensors via an IO-Link master.
Features
–Rectangular version
1 IO-Link interface
1 analog input for connecting resistance temperature
detectors (RTDs)
Connection of the sensor in 3-wire technology
IO-Link and sensor connections via M12 connectors
FE connection for local connection to functional earth
ground
Supply of the module electronics and the sensor via the
IO-Link interface of the IO-Link master
Diagnostic indicator
Make sure you always use the latest documentation.
It can be downloaded from the product at phoenixcontact.net/products
.
8590_en_06
2014-09-22
AXL E IOL RTD1 M12 R
8590_en_06 PHOENIX CONTACT 2
2Table of contents
1 Description .............................................................................................................................. 1
2 Table of contents ..................................................................................................................... 2
3 Ordering data .......................................................................................................................... 3
4 Technical data ......................................................................................................................... 3
5 Additional tables ...................................................................................................................... 5
6 Internal circuit diagram ............................................................................................................ 5
7 Pin assignment ........................................................................................................................ 6
7.1 Connections on the device..................................................................................................... 6
7.2 Pin assignment of the IO-Link interface ..................................................................................... 6
7.3 Pin assignment of the analog input........................................................................................... 6
8 Connection notes .................................................................................................................... 6
9 Connection example................................................................................................................ 6
10 Assembly................................................................................................................................. 7
11 Local status indicator............................................................................................................... 7
12 Process data............................................................................................................................ 8
12.1 IN process data................................................................................................................... 8
12.2 OUT process data................................................................................................................ 8
12.3 Parameterization via OUT process data .................................................................................... 9
12.4 Example............................................................................................................................ 9
13 Significant values in various formats...................................................................................... 10
13.1 IB IL format ...................................................................................................................... 10
13.2 S7-compatible format ......................................................................................................... 10
14 IO-Link objects ...................................................................................................................... 11
14.1 Overview of the objects ....................................................................................................... 11
14.2 Parameterization (80
hex
: ParaWord)....................................................................................... 12
AXL E IOL RTD1 M12 R
8590_en_06 PHOENIX CONTACT 3
Description Type Order No. Pcs. / Pkt.
AxiolineE-IO-Link/analog converter for connecting a temperature mea-
surement resistor, M12 fast connection technology, rectangular version
AXL E IOL RTD1 M12 R 2700305 1
3Ordering data
Dimensions (nominal sizes in mm)
Width 16.6 mm
Height 42 mm
Depth 66.5 mm
4 Technical data
50
66,5
28
29
41
16,6
General data
Weight 34 g
Ambient temperature (operation) -25 °C ... 60 °C
Ambient temperature (storage/transport) -25 °C ... 85 °C
Permissible humidity (operation) 5 % ... 95 %
Permissible humidity (storage/transport) 5 % ... 95 %
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protection IP65/67
Protection class III, IEC 61140, EN 61140, VDE 0140-1
Pollution degree 2
IO-Link
Specification V1.1.1
Protection against polarity reversal Yes
Transmission speed 230,4 kBit/s (COM3)
Frame type 1
Cycle Time min. 2 ms
Process data update 2 ms
Amount of process data 16 Bit (Input data), 16 Bit (Output data)
IO-Link ports
Number of ports 1
Connection method M12 connector, A-coded

2700305

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
TFT Displays & Accessories AXL E IOL RTD1 M12 R
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet