AXL E IOL RTD1 M12 R
8590_en_06 PHOENIX CONTACT 10
13 Significant values in various formats
13.1 IB IL format
13.2 S7-compatible format
Input data R 0 ... 500 R 0 ... 5k Temperature sensors
Resolution 0.1 1 0.1 °C * 0.1 °F *
hex dec °C °F
8003 Short-circuit no (0 )no (0 )yes yes
8002 Wire break yes yes yes yes
8001 Overrange > 525 > 5250 > 850 >1562
3D04 15620 - - - 1562
2134 8500 - - 850 850
1482 5250 525 5250 525 525
03E8 1000 100 1000 100 100
0032 50 5 50 5 5
0005 5 0.5 5 0.5 0.5
0001 1 0.1 1 - -
0000 0 0 0 0 0
FC18 -1000 - - -100 -100
F830 -2000 - - -200 -200
F330 -3280 - - - -328
8080 Underrange - - < -200 < -328
Input data R 0 ... 600 R 0 ... 6k Temperature sensors
Resolution 0.17 1.7 0.1 °C * 0.1 °F *
hex dec °C °F
8000 Short-circuit no (0 )no (0 )yes yes
8000 Wire break yes yes yes yes
7FFF Overrange > 705.4 > 7054 > 850 > 1562
7EF8 32504 705.4 7054 - -
3D04 15620 339 3390 - 1562
2134 8500 184.5 1845 850 850
03E8 1000 21.7 217 100 100
0032 50 1.1 11 50 50
0008 8 0.17 1.7 - -
0005 5 - - 0.5 0.5
0000 0 0 0 0 0
FC18 -1000 - - -100 -100
F830 -2000 - - -200 -200
F330 -3280 - - - < -328
8000 Underrange - - < -200 < -328
* The format representation is based on 0.1 °C/F. The actual resolution is 0.5 °C/F.
The measurement is thus always in 0.5 °C/F increments (steps).
AXL E IOL RTD1 M12 R
8590_en_06 PHOENIX CONTACT 11
14 IO-Link objects
14.1 Overview of the objects
Index (hex) Object name Length in
bytes
Access Meaning Contents
DPP ISDU
Identification
07 Vendor ID 2 R Manufacturer identifica-
tion
00
hex
08 B0
hex
09 Device ID 3 R Device ID 01
hex
0A 00
hex
0B 50
hex
10 VendorName Max. 64 R Manufacturer name Phoenix Contact
11 VendorText Max. 64 R Notes www.phoenixcontact.com
12 ProductName Max. 64 R Product designation AXL E IOL RTD1 M12 R
13 Product ID Max. 64 R Order No. 2700305
14 ProductText Max. 64 R Product text IO-Link/analog converter
temperature RTD input rect-
angular
15 Serial number Max. 16 R Serial number Stored in the production
process.
16 HardwareVersion Max. 64 R Hardware version E.g.,01
17 FirmwareVersion Max. 64 R Firmware version E.g.,001
Diagnostics
20 Error count 2 R Errors since power up Number of errors
28 InputProcessData 2 R Input process data Last current data
Parameter
80 ParaWord 2 R/W Parameterization 0000
hex
Abbreviation Meaning
RRead
WWrite
AXL E IOL RTD1 M12 R
8590_en_06 12
PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany
phoenixcontact.com
14.2 Parameterization (80
hex
: ParaWord)
Parameterize the device using this object.
In the case of valid parameters, the parameterization is permanently stored on the device.
After a reset, the device operates with the last permanently stored data. Upon delivery, the device operates with the default
data (default settings).
In the following tables the values in bold are default settings.
Saving data to the device leads to a communication failure of around30ms.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Reserved Resolution for sensor
type
Format Sensor type
Sensor type
Code (bin) Meaning
0000 Pt 100 DIN
0001 Pt 1000 SAMA
1110 IB IL format:
Linear R 0Ω ... 500Ω
S7-compatible format:
Linear R 0Ω ... 600
1111 IB IL format:
Linear R 0Ω ... 5k
S7-compatible format
Linear R 0Ω ... 6 k
Other Reserved
Format
Code (bin) Meaning
00 S7-compatible
10 IB IL
Other Reserved
Resolution for sensor type
Code (bin) Temperature sensors Linear R 0 ... 500 / 600 Linear R 0 ... 5k / 6 k
00 0.1 °C
(0.5 °C increments)
IB IL format: 0,1
S7-compatible format: 0,17
Format IB IL: 1,0
Format S7-kompatibel: 1,7
10 0.1 °F
(0.5 °F increments)
Reserved Reserved
Other Reserved

2700305

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
TFT Displays & Accessories AXL E IOL RTD1 M12 R
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet