Table 9. Control Location (CL[15:0])
FIELD NAME DESCRIPTION
15:8 CL[15:8] Reserved
7:0 CL[7:0]
Control Location. Secure-Lock is activated by setting this to FFhex which disables DIO serial
communications and connects OUT to PGA output.
Table 10. IRSA Decoding
IRSA[3:0] DESCRIPTION
0000 Write IRSD[3:0] to DHR[3:0] (data hold register)
0001 Write IRSD[3:0] to DHR[7:4] (data hold register)
0010 Write IRSD[3:0] to DHR[11:8] (data hold register)
0011 Write IRSD[3:0] to DHR[15:12] (data hold register)
0100 Reserved
0101 Reserved
0110
Write IRSD[3:0] to ICRA[3:0] or IEEA[3:0], (internal calibration register address or internal EEPROM address
nibble 0)
0111 Write IRSD[3:0] to IEEA[7:4] (internal EEPROM address, nibble 1)
1000 Write IRSD[3:0] to IRSP[3:0] or IEEA[9:8], (interface register set pointer where IRSP[1:0] is IEEA[9:8])
1001 Write IRSD[3:0] to CRIL[3:0] (command register to internal logic)
1010 Write IRSD[3:0] to ATIM[3:0] (analog timeout value on read)
1011 Write IRSD[3:0] to ALOC[3:0] (analog location)
1100 to 1110 Reserved
1111 Write IRSD[3:0] = 1111bin to relearn the baud rate
MAX1452
Low-Cost Precision Sensor
Signal Conditioner
20 ______________________________________________________________________________________
Table 11. CRIL Command Codes
CRIL[3:0] NAME DESCRIPTION
0000 LdICR Load internal calibration register at address given in ICRA with data from DHR[15:0].
0001 EEPW EEPROM write of 8 data bits from DHR[7:0] to address location pointed by IEEA[9:0].
0010 ERASE Erase all of EEPROM (all bytes equal FFhex).
0011 RdICR Read internal calibration register as pointed to by ICRA and load data into DHR[15:0].
0100 RdEEP Read internal EEPROM location and load data into DHR[7:0] pointed by IEEA[9:0].
0101 RdIRS Read interface register set pointer IRSP[3:0]. See Table 13.
0110 RdAlg
Output the multiplexed analog signal onto OUT. The analog location is specified in ALOC[3:0]
(Table 15) and the duration (in byte times) that the signal is asserted onto the pin is specified in
ATIM[3:0] (Table 14).
0111 PageErase
Erases the page of the EEPROM as pointed by IEEA[9:6]. There are 64 bytes per page and thus 12
pages in the EEPROM.
1000 to
1111
Reserved Reserved.
Table 12. ICRA[3:0] Decode
ICRA[3:0] NAME DESCRIPTION
0000 CONFIG Configuration Register
0001 ODAC Offset DAC Register
0010 OTCDAC Offset Temperature Coefficient DAC Register
0011 FSODAC Full Scale Output DAC Register
0100 FS O TC D AC Full Scale Output Temperature Coefficient DAC Register
0101 Reserved. Do not write to this location (EEPROM test).
0110 to
1111
Reserved. Do not write to this location.
MAX1452
Low-Cost Precision Sensor
Signal Conditioner
______________________________________________________________________________________ 21
Table 14. ATIM Definition
ATIM[3:0] DURATION OF ANALOG SIGNAL SPECIFIED IN BYTE TIMES (8-BIT TIME)
0000 2
0
+ 1 = 2 byte times i.e. (2
8)/baud rate
0001 2
1
+ 1 = 3 byte times
0010 2
2
+ 1 = 5 byte times
0011 2
3
+ 1 = 9 byte times
0100 2
4
+ 1 = 17 byte times
0101 2
5
+ 1 = 33 byte times
0110 2
6
+ 1 = 65 byte times
0111 2
7
+ 1 = 129 byte times
1000 2
8
+ 1 = 257 byte times
1001 2
9
+ 1 = 513 byte times
1010 2
10
+ 1 = 1025 byte times
1011 2
11
+ 1 = 2049 byte times
1100 2
12
+ 1 = 4097 byte times
1101 2
13
+ 1 = 8193 byte times
1110 2
14
+ 1 = 16,385 byte times
1111
In this mode OUT is continuous, however DIO accepts commands after 32,769 byte times. Do not parallel
connect DIO to OUT.
Table 13. IRSP Decode
IRSP[3:0] RETURNED VALUE
0000 DHR[7:0]
0001 DHR[15:8]
0010 IEEA[7:4], ICRA[3:0] concatenated
0011 CRIL[3:0], IRSP[3:0] concatenated
0100 ALOC[3:0], ATIM[3:0] concatenated
0101 IEEA[7:0] EEPROM address byte
0110 IEED[7:0] EEPROM data byte
0111 TEMP-Index[7:0]
1000 BitClock[7:0]
1001 Reserved. Internal flash test data.
1010-1111 11001010 (CAhex). This can be used to test communication.