SL28647
.....................Document #: 001-05103 Rev *B Page 22 of 27
LCD_100_SSC at 0.7V
T
DC
LCD_100 Duty Cycle Measured at 0V differential 45 55 %
T
PERIOD
100 MHz LCD_100 Period Measured at 0V differential at 0.1s 9.99900 10.0010 ns
T
PERIODSS
100 MHz LCD_100 Period, SSC
-0.5%
Measured at 0V differential at 0.1s 10.0240
6
10.0260
7
ns
T
PERIODAbs
100 MHz LCD_100 Absolute Period Measured at 0V differential at 1 clock 9.74900 10.2510
0
ns
T
PERI-
ODSSAbs
100 MHz LCD_100 Absolute Period,
SSC
Measured at 0V differential @ 1 clock 9.74906 10.3012 ns
T
CCJ
LCD_100 Cycle to Cycle Jitter Measured at 0V differential 250 ps
L
ACC
LCD_100 Long Term Accuracy Measured at 0V differential 100 ppm
T
R
/ T
F
LCD_100 Rising/Falling Slew Rate Measured differentially from ±150 mV 2.5 8 V/ns
T
RFM
Rise/Fall Matching Measured single-endedly from ±75 mV 20 %
V
HIGH
Voltage High 1.15 V
V
LOW
Voltage Low –0.3 V
V
OX
Crossing Point Voltage at 0.7V Swing 300 550 mV
PCI/PCIF at 3.3V
T
DC
PCI Duty Cycle Measurement at 1.5V 45 55 %
T
PERIOD
Spread Disabled PCIF/PCI Period Measurement at 1.5V
29.99700 30.00300
ns
T
PERIODSS
Spread Enabled PCIF/PCI Period Measurement at 1.5V
30.08421 30.23459
ns
T
PERIODAbs
Spread Disabled PCIF/PCI Period Measurement at 1.5V
29.49700 30.50300
ns
T
PERI-
ODSSAbs
Spread Enabled PCIF/PCI Period Measurement at 1.5V
29.56617 30.58421
ns
T
HIGH
Spread Enabled PCIF and PCI high
time
Measurement at 2V 12.2709
5
16.2799
5
ns
T
LOW
Spread Enabled PCIF and PCI low
time
Measurement at 0.8V 11.8709
5
16.0799
5
ns
T
HIGH
Spread Disabled PCIF and PCI high
time
Measurement at 2.V 12.2736
5
16.2766
5
ns
T
LOW
Spread Disabled PCIF and PCI low
time
Measurement at 0.8V 11.8736
5
16.0766
5
ns
T
R
/ T
F
PCIF/PCI Rising/Falling Slew Rate Measured between 0.8V and 2.0V 1.0 4.0 V/ns
T
SKEW
Any PCI clock to Any PCI clock Skew Measurement at 1.5V 1000 ps
T
CCJ
PCIF and PCI Cycle to Cycle Jitter Measurement at 1.5V 500 ps
L
ACC
PCIF/PCI Long Term Accuracy Measurement at 1.5V 100 ppm
48_M at 3.3V
T
DC
Duty Cycle Measurement at 1.5V 45 55 %
T
PERIOD
Period Measurement at 1.5V
20.83125 20.83542
ns
T
PERIODAbs
Absolute Period Measurement at 1.5V
20.48125 21.18542
ns
T
HIGH
48_M High time Measurement at 2V
8.216563 11.15198
ns
T
LOW
48_M Low time Measurement at 0.8V
7.816563 10.95198
ns
T
R
/ T
F
Rising and Falling Edge Rate Measured between 0.8V and 2.0V 1.0 2.0 V/ns
T
CCJ
Cycle to Cycle Jitter Measurement at 1.5V 350 ps
L
ACC
48M Long Term Accuracy Measurement at 1.5V 100 ppm
27M_NSS/27M_SS at 3.3V
T
DC
Duty Cycle Measurement at 1.5V 45 55 %
AC Electrical Specifications (continued)
Parameter Description Condition Min. Max. Unit
SL28647
.....................Document #: 001-05103 Rev *B Page 23 of 27
The information in this document is believed to be accurate in all respects at the time of publication but is subject to change without notice. Sil-
icon Laboratories assumes no responsibility for errors and omissions, and disclaims responsibility for any consequences resulting from the
use of information included herein. Additionally, Silicon Laboratories assumes no responsibility for the functioning of undescribed features or
parameters. Silicon Laboratories reserves the right to make changes without further notice. Silicon Laboratories makes no warranty, repre-
sentation or guarantee regarding the suitability of its products for any particular purpose, nor does Silicon Laboratories assume any liability
arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation conse-
quential or incidental damages. Silicon Laboratories products are not designed, intended, or authorized for use in applications intended to
support or sustain life, or for any other application in which the failure of the Silicon Laboratories product could create a situation where per-
sonal injury or death may occur. Should Buyer purchase or use Silicon Laboratories products for any such unintended or unauthorized appli-
cation, Buyer shall indemnify and hold Silicon Laboratories harmless against all claims and damages.
Test and Measurement Set-up
For Single-ended Signals and Reference
The following diagram shows test load configurations for the
single-ended PCI, USB, and REF output signals.
T
PERIOD
Spread Disabled 27M Period Measurement at 1.5V 37.0359
4
37.0381
3
ns
Spread Enabled 27M Period Measurement at 1.5V 37.0129
86
37.1317
2
ns
T
R
/ T
F
Rising and Falling Edge Rate Measured between 0.8V and 2.0V 1.0 4.0 V/ns
T
CCJ
Cycle to Cycle Jitter Measurement at 1.5V 200 ps
L
ACC
27_M Long Term Accuracy Measured at crossing point V
OX
50 ppm
REF
T
DC
REF Duty Cycle Measurement at 1.5V 45 55 %
T
PERIOD
REF Period
Measurement at 1.5V 69.82033 69.86224 ns
T
PERIODAbs
REF Absolute Period
Measurement at 1.5V 68.83429 70.84826 ns
T
HIGH
REF High time
Measurement at 2V 29.97543 38.46654 ns
T
LOW
REF Low time
Measurement at 0.8V 29.57543 38.26654 ns
T
R
/ T
F
REF Rising and Falling Edge Rate Measured between 0.8V and 2.0V 1.0 4.0 V/ns
T
SKEW
REF Clock to REF Clock Measurement at 1.5V 500 ps
T
CCJ
REF Cycle to Cycle Jitter Measurement at 1.5V 1000 ps
L
ACC
Long Term Accuracy Measurement at 1.5V 100 ppm
ENABLE/DISABLE and SET-UP
T
STABLE
Clock Stabilization from Power-up 1.8 ms
T
SS
Stopclock Set-up Time 10.0 ns
AC Electrical Specifications (continued)
Parameter Description Condition Min. Max. Unit
Figure 15.Single-ended Load Configuration Low Drive Option
SL28647
.....................Document #: 001-05103 Rev *B Page 24 of 27
The following diagram shows the test load configuration for the
differential CPU and SRC outputs.
Figure 16. Single-ended Load Configuration High Drive Option
Figure 17. 0.8V Differential Load
2.0V
0.8V
3.3V
0V
T
R
T
F
1.5V
3.3V signals
T
DC
-
-
Figure 18. Single-ended Output Signals (for AC Parameters Measurement)

SL28647BLCT

Mfr. #:
Manufacturer:
Silicon Labs
Description:
Clock Generators & Support Products Montevina
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet