TQ
–4–
ASCTB14E 201407-T
3) 2 coil latching (2 Form C)
[M.B.B. type]
*Pulse drive (JIS C 5442-1986)
2. Specifications
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. TX/TX-S/TX-D relay AgPd contact type are available for low level load switching (10V DC, 10mA max. level).
*2 Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES.
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
Set coil Reset coil Set coil Reset coil Set coil Reset coil
3 V DC
75%V or less of
nominal voltage*
(Initial)
75%V or less of
nominal voltage*
(Initial)
66.7 mA 66.7 mA 45 Ω 45 Ω
200 mW 200 mW
150%V of
nominal voltage
4.5 V DC 44.4 mA 44.4 mA 101.2 Ω 101.2 Ω
5 V DC 40 mA 40 mA 125 Ω 125 Ω
6 V DC 33.3 mA 33.3 mA 180 Ω 180 Ω
9 V DC 22.2 mA 22.2 mA 405 Ω 405 Ω
12 V DC 16.7 mA 16.7 mA 720 Ω 720 Ω
24 V DC 12.5 mA 12.5 mA 1,920 Ω 1,920 Ω 300 mW 300 mW
120%V of
nominal voltage
Nominal coil
voltage
Pick-up voltage
(at 20°C
68°F)
Drop-out v
oltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
3 V DC
80%V or less of
nominal voltage*
(Initial)
10%V or more of
nominal voltage*
(Initial)
66.7 mA 45 Ω
200 mW
150%V of
nominal voltage
4.5 V DC 44.4 mA 101 Ω
5 V DC 40 mA 125 Ω
6 V DC 33.3 mA 180 Ω
9 V DC 22.2 mA 405 Ω
12 V DC 16.7 mA 720 Ω
24 V DC 8.3 mA 2,880 Ω
Characteristics Item Specifications
Contact
Arrangement 2 Form C, 2 Form D (M.B.B.)
Initial contact resistance, max. Max. 50mΩ (By voltage drop 6 V DC 1A)
Contact material Ag+Au clad
Rating
Nominal switching capacity 1 A 30 V DC, 0.5 A 125 V AC (resistive load)
Max. switching power 30 W (DC), 62.5 V A (AC) (resistive load)
Max. switching voltage 110 V DC, 125 V AC
Max. switching current 1 A
Min. switching capacity (Reference value)*
1
10μA 10mV DC
Nominal
operating power
Single side stable
Standard (B.B.M) type: 140 mW (3 to 12 V DC), 200 mW (24 V DC), 300 mW (48 V DC)
M.B.B. type: 200 mW
1 coil latching 100 mW (3 to 12 V DC), 150 mW (24 V DC)
2 coil latching 200 mW (3 to 12 V DC), 300 mW (24 V DC)
Electrical
characteristics
Insulation resistance (Initial)
Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Breakdown
voltage (Initial)
Between open contacts
Standard (B.B.M) type: 750 Vrms for 1min. (Detection current: 10 mA),
M.B.B. type: 300 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 1,000 Vrms for 1min. (Detection current: 10 mA)
Between contact sets 1,000 Vrms for 1min. (Detection current: 10 mA)
Temperature rise (at 20°C 68°F) Max. 50°C (By resistive method, nominal coil voltage applied to the coil; contact carrying current: 1A.)
Operate time [Set time] (at 20°C 68°F) Max. 3 ms [Max. 3 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time [Reset time] (at 20°C 68°F)
Max. 3 ms [Max. 3 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Mechanical
characteristics
Shock
resistance
Functional Min. 490 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Destructive Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration
resistance
Functional 10 to 55 Hz at double amplitude of 3 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 5 mm
Expected life
Mechanical (at 180 cpm) Standard (B.B.M) type: Min. 10
8
, M.B.B. type: Min. 10
7
Electrical (at 20 cpm)
Standard (B.B.M) type: Min. 2×10
5
(1 A 30 V DC resistive), Min. 10
5
(0.5 A 125 V AC resistive)
M.B.B. type: Min. 10
5
(1 A 30 V DC resistive)
Conditions
Conditions for operation, transport and
storage*
2
Standard (B.B.M) type:
Ambient temperature: –40°C to +70°C –40°F to +158°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
M.B.B. type:
Ambient temperature: –40°C to +50°C –40°F to +122°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load) 20 cpm
Unit weight Approx. 1.5 g .053 oz
TQ
–5–
ASCTB14E 201407-T
Surface-mount terminal
1. Coil data
1) Single side stable
2) 1 coil latching
3) 2 coil latching
*Pulse drive (JIS C 5442-1986)
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
(at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
1.5 V DC
75%V or less of
nominal voltage*
(Initial)
10%V or more of
nominal voltage*
(Initial)
93.8 mA 16 Ω
140 mW
150%V of
nominal voltage
3 V DC 46.7 mA 64.3 Ω
4.5 V DC 31 mA 145 Ω
5 V DC 28.1 mA 178 Ω
6 V DC 23.3 mA 257 Ω
9 V DC 15.5 mA 579 Ω
12 V DC 11.7 mA 1,028 Ω
24 V DC 8.3 mA 2,880 Ω 200 mW
48 V DC 6.3 mA 7,680 Ω 300 mW
120%V of
nominal voltage
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
Nominal operating
current
(at 20
°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal oper
ating
power
Max. applied voltage
(at 20°C 68°F)
1.5 V DC
75%V or less of
nominal voltage*
(Initial)
75%V or less of
nominal voltage*
(Initial)
46.9 mA 32 Ω
70 mW
150%V of
nominal voltage
3 V DC 23.3 mA 128.6 Ω
4.5 V DC 15.6 mA 289.3 Ω
5 V DC 14 mA 357 Ω
6 V DC 11.7 mA 514 Ω
9 V DC 7.8 mA 1,157 Ω
12 V DC 5.8 mA 2,057 Ω
24 V DC 4.2 mA 5,760 Ω 100 mW
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
Nominal operating
current
(at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
Set coil Reset coil Set coil Reset coil Set coil Reset coil
1.5 V DC
75%V or less of
nominal v
oltage*
(Initial)
75%V or less of
nominal voltage*
(Initial)
93.8 mA 93.8 mA 16 Ω 16 Ω
140 mW 140 mW
150%V of
nominal voltage
3 V DC 46.7 mA 46.7 mA 64.3 Ω 64.3 Ω
4.5 V DC 31 mA 31 mA 145 Ω 145 Ω
5 V DC 28.1 mA 28.1 mA 178 Ω 178 Ω
6 V DC 23.3 mA 23.3 mA 257 Ω 257 Ω
9 V DC 15.5 mA 15.5 mA 579 Ω 579 Ω
12 V DC 11.7 mA 11.7 mA 1,028 Ω 1,028 Ω
24 V DC 8.3 mA 8.3 mA 2,880 Ω 2,880 Ω 200 mW 200 mW
TQ
–6–
ASCTB14E 201407-T
2. Specifications
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. (TX/TX-S/TX-D relay AgPd contact type are available for low level load switching [10V DC, 10mA max. level])
*2 Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES.
Characteristics Item Specifications
Contact
Arrangement 2 Form C
Initial contact resistance, max. Max. 75 mΩ (By voltage drop 6 V DC 1A)
Contact material AgNi type+Au clad
Rating
Nominal switching capacity 2 A 30 V DC, 0.5 A 125 V AC (resistive load)
Max. switching power 60 W (DC), 62.5 VA (AC) (resistive load)
Max. switching voltage 220 V DC, 125 V AC
Max. switching current 2 A
Min. switching capacity (Reference value)*
1
10μA 10mV DC
Nominal operating
power
Single side stable 140 mW (1.5 to 12 V DC), 200 mW (24 V DC), 300 mW (48 V DC)
1 coil latching 70 mW (1.5 to 12 V DC), 100 mW (24 V DC)
2 coil latching 140 mW (1.5 to 12 V DC), 200 mW (24 V DC)
Electrical
characteristics
Insulation resistance (Initial)
Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 1,500 Vrms for 1 min. (Detection current: 10 mA)
Between contact sets 1,500 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown
voltage (Initial)
Between open contacts 1,500 V (10×160μs) (FCC Part 68)
Between contacts and coil 2,500 V (2×10μs) (Bellcore)
Temperature rise (at 20°C 68°F)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A.)
Operate time [Set time] (at 20°C 68°F)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.)
Release time [Reset time] (at 20°C 68°F)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.) (without diode)
Mechanical
characteristics
Shock resistance
Functional Min. 750 m/s
2
(Half-wave pulse of sine wave: 6 ms; detection time: 10μs.)
Destructive Min. 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 5 mm
Expected life
Mechanical Min. 10
8
(at 180 cpm)
Electrical
Min. 10
5
(2 A 30 V DC resistive), Min. 2×10
5
(1 A 30 V DC resistive),
Min. 10
5
(0.5 A 125 V AC resistive) (at 20 cpm)
Conditions
Conditions for operation, transport and storage*
2
Ambient temperature:
–40°C to +85°C –40°F to +185°F, Max. –40°C to +70°C (2A) Max. –40°F to +158°F (2A);
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load) 20 cpm
Unit weight Approx. 2 g .071 oz

TQ2-24V

Mfr. #:
Manufacturer:
Panasonic Industrial Devices
Description:
Low Signal Relays - PCB 1A 24VDC DPDT NON-LATCHING PCB
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union