8
Optical Specifications
Parameter Symbol Conditions Minimum Maximum Units
Sensor operating detection range E
V
(Note 3 &10) 800 10000 Lux
Serial Interface Timing Information
Parameter Symbol Minimum Maximum Units
SCL clock frequency f
scl
0 100 kHz
(Repeated) START condition hold time t
HD:STA
4-
µs
Data hold time t
HD:DAT
03.45
µs
SCL clock low period t
LOW
4.7 -
µs
SCL clock high period t
HIGH
4.0 -
µs
Repeated START condition setup time t
SU:STA
4.7 -
µs
Data setup time t
SU:DAT
250 - ns
STOP condition setup time t
SU:STO
4.0 -
µs
Bus free time between START and STOP conditions t
BUF
4.7 -
µs
Figure 1. Serial Interface Bus Timing Waveforms
SDA
SCL
t
HD:STA
t
LOW
t
HIGH
t
SU:DAT
t
HD:DAT
t
SU:STO
t
BUF
S PS
t
SU:STA
t
HD:STA
Sr
Notes:
1. The “Absolute Maximum Ratings” are those values beyond which damage to the device may occur. The device should not be operated at
these limits. The parametric values defined in the “Electrical Specifications” table are not guaranteed at the absolute maximum ratings. The
“Recommended Operating Conditions” table will define the conditions for actual device operation.
2. Unless otherwise specified, all voltages are referenced to ground.
3. Specified at room temperature (25°C) and VDDD = VDDA = 2.6V.
4. Applies to all digital input pins.
5. Applies to all digital output pins and CLKIO pin. SDASLV and SDAPROM pins go tri-state when output logic high. Minimum V
OH
depends on
the pull-up resistor value.
6. Applies to all digital output and digital input-output pins.
7. Dynamic testing is performed with the IC operating in a mode representative of typical operation.
8. Refers to total device current consumption.
9. Output and bidirectional pins are not loaded.
10. Using R:G:B LED light source brightness ratio of 7:13:1 to achieve white D90 color point
Red LED (x,y) = (0.700, 0.300)
Green LED (x,y) = (0.171, 0.715)
Blue LED (x,y) = (0.158, 0.019)