Nexperia
74AUP1G97
Low-power configurable multiple function gate
74AUP1G97 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 10 — 28 March 2017
6 / 25
9 Limiting values
Table 6. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol Parameter Conditions Min Max Unit
V
CC
supply voltage -0.5 +4.6 V
I
IK
input clamping current V
I
< 0 V -50 - mA
V
I
input voltage
[1]
-0.5 +4.6 V
I
OK
output clamping current V
O
< 0 V -50 - mA
V
O
output voltage Active mode and Power-down
mode
[1]
-0.5 +4.6 V
I
O
output current V
O
= 0 V to V
CC
- ±20 mA
I
CC
supply current - 50 mA
I
GND
ground current -50 - mA
T
stg
storage temperature -65 +150 °C
P
tot
total power dissipation T
amb
= -40 °C to +125 °C
[2]
- 250 mW
[1] The minimum input and output voltage ratings may be exceeded if the input and output current ratings are observed.
[2] For SC-88 package: above 87.5 °C the value of P
tot
derates linearly with 4.0 mW/K.
For X2SON6 and XSON6 packages: above 118 °C the value of P
tot
derates linearly with 7.8 mW/K.
For WLCSP6 package: above 102.5 °C the value of P
tot
derates linearly with 5.3 mW/K.
10 Recommended operating conditions
Table 7. Recommended operating conditions
Symbol Parameter Conditions Min Max Unit
V
CC
supply voltage 0.8 3.6 V
V
I
input voltage 0 3.6 V
Active mode 0 V
CC
VV
O
output voltage
Power-down mode; V
CC
= 0 V 0 3.6 V
T
amb
ambient temperature -40 +125 °C