SERCON816
12/23
3.5.4 Read Access of Control Registers
Figure 8. Read Access of Control Registers
Note: 1. Setup time input signals to falling edge RDN (Intel or Motorola mode with low active strobe) or rising edge RDN (Motorola mode
with high active strobe)
Symbol Parameter Min. Typ. Max. Unit
t
ASU
Setup time A6-0, (Note 1) 10 ns
Setup time BHEN, PCSN0, PCS1, DMAACKNR, WRN (only
Motorola mode),
(Note 1)
0ns
t
AHD
Hold time A6-0, BHEN, PCSN0, PCS1, DMAACKNR, WRN
(only Motorola mode) to rising edge RDN (Intel Motorola
mode with low active strobe) or falling edge RDN (Motorola
mode with high active strobe)
0ns
t
PAD
Access time A6-0, BHEN, PCSN0, PCS1, DMAACKNR,
WRN (only Motorola mode) to D15-0 valid
30 ns
t
PRDD
Access time RDN to D15-0 valid 30 ns
t
RDZ
Delay RDN to D15-0 high-Z 20 ns
t
PRQ
Delay RDN to DMAREQR low 20 ns
A6-0, BHEN
PCSN0, PCS1,
DMAACKNR,
WRN (Motorola mode)
RDN
D15-0
DMAREQR
t
PAD
t
PRQ
t
RD Z
t
PRDD
t
AHD
t
ASU