Limitation of the voltage induced on circuit interruption -28 V ... -17 V
Output voltage when switched off max. 1 V
Output current when switched off max. 20 µA
Behavior with overload Auto restart
Reverse voltage resistance to short pulses Reverse voltage proof
Overcurrent shut-down min. 0.7 A
Overload protection, short-circuit protection of outputs Electronic
Electrical isolation/isolation of the voltage areas
Test section Te s t vo l t a g e
24 V supply (communications power and sensor supply, digital inputs)/
bus connection (Ethernet1)
500 V AC, 50 Hz, 1 min
24 V supply (communications power and sensor supply, digital inputs)/
bus connection (Ethernet2)
500 V AC, 50 Hz, 1 min
24 V supply (communications power and sensor supply, digital inputs)/FE 500 V AC, 50 Hz, 1 min
Bus connection (Ethernet1)/FE 500 V AC, 50 Hz, 1 min
Bus connection (Ethernet2)/FE 500 V AC, 50 Hz, 1 min
Bus connection (Ethernet1)/bus connection (Ethernet2) 500 V AC, 50 Hz, 1 min
24 V supply (actuator supply, digital outputs)/
24 V supply (communications power and sensor supply, digital inputs)
500 V AC, 50 Hz, 1 min
24 V supply (actuator supply, digital outputs)/bus connection (Ethernet1) 500 V AC, 50 Hz, 1 min
24 V supply (actuator supply, digital outputs)/bus connection (Ethernet2) 500 V AC, 50 Hz, 1 min
24 V supply (actuator supply, digital outputs)/FE 500 V AC, 50 Hz, 1 min
Mechanical tests
Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5 g
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30 g, 11 ms period, half-sine shock pulse
Continuous shock according to EN60068-2-27/IEC60068-2-27 10 g
Conformance with EMC Directive 2004/108/EC
Noise immunity test in accordance with EN 61000-6-2
Electrostatic discharge (ESD) EN61000-4-2/IEC61000-4-2 Criterion B; 6 kV contact discharge, 8 kV air discharge
Electromagnetic fields EN61000-4-3/IEC61000-4-3 Criterion A; Field intensity: 10 V/m
Fast transients (burst) EN61000-4-4/IEC61000-4-4 Criterion B, 2kV
Transient surge voltage (surge) EN61000-4-5/IEC61000-4-5 Criterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
Conducted interference EN61000-4-6/IEC61000-4-6 Criterion A; Test voltage 10 V
Noise emission test as per EN 61000-6-4
Radio interference properties EN 55022 Class A