DC and AC parameters M95040, M95020, M95010
26/42
9 DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristic tables that
follow are derived from tests performed under the measurement conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
1. Output Hi-Z is defined as the point where data out is no longer driven.
Figure 14. AC test measurement I/O waveform
Table 8. Operating conditions (M950x0)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 4.5 5.5 V
T
A
Ambient operating temperature (device grade 3) –40 125 °C
Table 9. Operating conditions (M950x0-W)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 2.5 5.5 V
T
A
Ambient operating temperature (device grade 6) –40 85 °C
Ambient operating temperature (device grade 3) –40 125 °C
Table 10. Operating conditions (M950x0-R)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.8 5.5 V
T
A
Ambient operating temperature –40 85 °C
Table 11. AC test measurement conditions
Symbol Parameter Min. Max. Unit
C
L
Load capacitance 30 pF
Input rise and fall times 50 ns
Input pulse voltages 0.2V
CC
to 0.8V
CC
V
Input and output timing reference voltages 0.3V
CC
to 0.7V
CC
V
AI00825B
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC
Input and Output
Timing Reference Levels
Input Levels