ADM1191 Data Sheet
Rev. C | Page 4 of 16
Parameter Min
Typ
Max
Unit
Conditions
A0 PIN, A1 PIN
Set Address to 00, V
ADRLOWV
0
0.8
V
Low state
Set Address to 01, R
ADRLOWZ
80
120
160
kΩ
Resistor to ground state, load pin with
specified resistance for 01 decode
Set Address to 10, I
ADRHIGHZ
−0.3 +0.3 µA Open state, maximum load allowed
on the A0 pin or A1 pin for 10 decode
Set Address to 11, V
ADRHIGHV
2
5.5
V
High state
Input Current for 00 Decode, I
ADRLOW
−40 −25
µA
V
ADR
= 0 V to 0.8 V
Input Current for 11 Decode, I
ADRHIGH
3
6 µA
V
ADR
= 2.0 V to 5.5 V
I
2
C TIMING
Low Level Input Voltage, V
IL
0.3 V
BUS
V V
BUS
= 3.0 V to 5.5 V
High Level Input Voltage, V
IH
0.7 V
BUS
V V
BUS
= 3.0 V to 5.5 V
Low Level Output Voltage on SDA, V
OL
0.4 V I
OL
= 3 mA
Output Fall Time on SDA from V
IHMIN
ILMAX
BUS
BUS
= bus capacitance from SDA to GND
Maximum Width of Spikes Suppressed by
Input Filtering on SDA and SCL Pins
50 250 ns
Input Current, I
I
, on SDA/SCL When Not
Driving a Logic Low Output
−10 +10 µA
Input Capacitance on SDA/SCL
5 pF
SCL
Low Period of the SCL Clock
600 ns
High Period of the SCL Clock
1300 ns
Setup Time for Repeated Start Condition, t
SU;STA
600 ns
SDA Output Data Hold Time, t
HD;DAT
100 900 ns
Setup Time for a Stop Condition, t
SU;STO
600 ns
Bus Free Time Between a Stop and a Start
Condition, t
BUF
1300 ns
Capacitive Load for Each Bus Line
400 pF
1
Monitoring accuracy is a measure of the error in a code that is read back for a particular voltage/current. This is a combination of amplifier error, reference error, ADC
error, and error in ADC full-scale code conversion factor.
2
This is an absolute value to be used when converting ADC codes to current readings; any inaccuracy in this value is factored into absolute current accuracy values (see
the specifications for the Current Sense Absolute Accuracy parameter).
3
These are absolute values to be used when converting ADC codes to voltage readings; any inaccuracy in these values is factored into voltage accuracy values (see the
specifications for the Voltage Sense Accuracy parameter).
4
Time between the receipt of the command byte and the actual ADC result being placed in the register.