DATA SHEET
SE2614BT: 2.4 GHz High Efficiency Wireless LAN Front-End
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
202394B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 9, 2014 7
Power Detector Characteristics
Conditions: VCC = EN = CTX = 3.3 V, CPORT1 = CPORT2 = 0 V, T
A = 25 C, as measured on Skyworks Solutions’
SE2614BT-EK1 evaluation board, unless otherwise noted.
Symbol Parameter Condition Min. Typ. Max. Unit
FOUT Frequency Range - 2400 - 2500 MHz
PDR
Power detect range,
CW
Measured at ANT 0 - 21 dBm
PDVNoRF
Output Voltage, P
OUT
=
No RF
Measured into 26K - 0.35 - V
PDVP18
Output Voltage, POUT
=
18 dBm CW
Measured into 26K - 0.68 - V
PDVP21
Output Voltage, P
OUT
=
22 dBm CW
Measured into 26K - 0.83 - V
Zout
Detector output
impedance
1 K
LPF-3dB
Power detect low pass
filter -3dB corner
frequency
PDCLOAD = High Z (1M) - 500 - KHz
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
11 12 13 14 15 16 17 18 19 20 21 22 23 24
Pout (dBm)
Pdet(V)
Figure 3: SE2614BT Power Detector Characteristics