MITSUBISHI SEMICONDUCTOR <Dual-In-Line Package Intelligent Power Module>
PS21267-P/AP
TRANSFER-MOLD TYPE
INSULATED TYPE
Oct. 2005
Fig. 6 PACKAGE OUTLINES (Long-pin type : PS21267-AP)
Irregular solder remains
Irregular solder remains
1
±0.2
(0.7)
(1)
0.6
±0.5
0.5MAX
C0.2
C0.2
(2.5)
0.8
±0.2
(0.6)
1
±0.2
0.7
±0.2
0.7
±0.2
0.6
±0.5
0.8
±0.2
0.45
±0.2
0.45
±0.2
0.8
±0.2
0.45
±0.2
(1)
0.5MAX
Type name , Lot No.
2625242322
1
(0 ~ 5°)
CB
8
±
0.5
Heat sink side
TERMINAL 22, 26
OTHERS
OTHERS
DETAIL B
(5 pins t = 0.7)
DETAIL C
(21 pins t = 0.7)
TERMINAL 1-2, 20-21
Heat sink side
16
±
0.5
2 3 4 5 6 7 8 9
10 1312 1514 16 17 18 19 20 2111
79
±
0.5
(71)
67
±
0.3
2-φ4.5
±
0.2
2.8
±
0.3
27×2.8(=75.6)
11.5
±
0.5
31
±
0.5
(11.5)(8.5)
28
±
0.5
0.5
±
0.2
DETAIL DDETAIL A
D
21.4
±
0.5
13.4
±
0.5
3.8
±
0.2
A
TERMINAL CODE
1. UP
2. VP1
3. VUFB
4. VUFS
5. VP
6. VP1
7. VVFB
8. VVFS
9. WP
10. VP1
11. VPC
12. VWFB
13. VWFS
14. VN1
15. VNC
16. CIN
17. CFO
18. FO
19. UN
20. VN
21. WN
22. P
23. U
24. V
25. W
26. N
20
±
0.3
10
±
0.3
10
±
0.3
10
±
0.3
NOTE
35
±
0.6
Note: All outer lead terminals are with Pb-free solder plating.
MITSUBISHI SEMICONDUCTOR <Dual-In-Line Package Intelligent Power Module>
PS21267-P/AP
TRANSFER-MOLD TYPE
INSULATED TYPE
Oct. 2005
Error output Fo
Output current Ic
Control supply voltage V
D
Protection circuit state
Control input
b1
b2
b3
b4
b5
RESET
RESET
UV
Dt
UV
Dr
SET
b6
b7
Protection circuit state
Lower-arms control
input
Error output Fo
Sense voltage of the
shunt resistance
Output current Ic
Internal IGBT gate
SC reference voltage
CR circuit time
constant DELAY
a5
a8
a4
a3
a1
a2
SC
RESET
SET
a7a6
Fig. 7 TIMING CHARTS OF THE DIP-IPM PROTECTIVE FUNCTIONS
[A] Short-Circuit Protection (Lower-arms only) (with external shunt resistor and CR connection)
a1. Normal operation : IGBT ON and carrying current.
a2. Short circuit current detection (SC trigger).
a3. Hard IGBT gate interrupt.
a4. IGBT turns OFF.
a5. F
O timer operation starts : The pulse width of the FO signal is set by the external capacitor CFO.
a6. Input “L” : IGBT OFF state.
a7. Input “H” : IGBT ON state, but during the F
O signal active period the IGBT doesn’t turn ON.
a8. IGBT OFF in spite of “H” input.
[B] Under-Voltage Protection (Lower-arm, UVD)
b1. Control supply voltage rises : After the voltage reaches UVDr level, the circuits start to operate when the next input is applied.
b2. Normal operation : IGBT ON and carrying current.
b3. Under voltage trip (UVDt).
b4. IGBT OFF in spite of control input condition.
b5. FO operation starts. The minimum pulse width of FO is set by the external capacitor CFO, and FO outputs continuously during UV period.
b6. Under voltage reset (UVDr).
b7. Normal operation : IGBT ON and carrying current.
MITSUBISHI SEMICONDUCTOR <Dual-In-Line Package Intelligent Power Module>
PS21267-P/AP
TRANSFER-MOLD TYPE
INSULATED TYPE
Oct. 2005
MCU
10k
U
P
,V
P
,W
P
,U
N
,V
N
,W
N
V
NC
(Logic)
Fo
DIP-IPM
5V line
[C] Under-Voltage Protection (Upper-arm, UVDB)
c1. Control supply voltage rises : Operation starts soon after UVDBr.
c2. Normal operation : IGBT ON and carrying current.
c3. Under voltage trip (UVDBt).
c4. IGBT OFF in spite of control input condition, but there is no FO signal output.
c5. Under voltage reset (UVDBr).
c6. Normal operation : IGBT ON and carrying current.
Fig. 8 RECOMMENDED MCU I/O INTERFACE CIRCUIT
Note : RC coupling at each input (parts shown dotted) might change depending on the PWM control scheme used in
the application and the wiring impedance of the application’s printed circuit board.
The DIP-IPM input signal section integrates a 2.5k(min) pull-down resistor. Therefore, if using external RC
filter, pay attention to satisfy the turn-on/off threshold voltage requirement.
Fig. 9 RECOMMENDED WIRING OF SHUNT RESISTOR
V
NC
N
DIP-IPM
Wiring inductance should be less than 10nH.
Shunt resistor
width=3mm, thickness=100µm, length=17mm
in copper pattern (rough standard)
Please make the connection point
as close as possible to the terminal
of shunt resistor.
Control input
Protection circuit state
Control supply voltage V
DB
Output current Ic
Error output Fo
High-level (no fault output)
UV
DBr
RESET SET
RESET
UV
DBt
c1
c3
c4
c5
c6
c7
c2

PS21267-AP

Mfr. #:
Manufacturer:
Description:
MOD IPM 600V 30A DIP