MAX8686
Single/Multiphase, Step-Down,
DC-DC Converter Delivers Up to 25A Per Phase
_______________________________________________________________________________________ 9
Pin Description (continued)
PIN NAME FUNCTION
33 FREQ
Frequency-Setting Input. Connect a capacitor from FREQ to GFREQ to set the switching frequency.
The triangle ramp runs between 0 and AVL/2. In multiphase applications, connect FREQ of the master
and all slave devices together. FREQ is internally pulled to GFREQ during shutdown.
34 SS
Soft-Start Input. For master-mode or single-phase operation, connect a capacitor from SS to GND to
set the soft-start time. A 25μA internal current source charges the capacitor. SS is pulled to GND in
shutdown. Connect SS to GND for slave mode operation.
35 ILIM
Analog Programmable Current Limit. Connect a resistor from ILIM to GND to set the current limit. A
10μA current source through this resistor sets the current-limit threshold. In multiphase applications,
connect ILIM of the master and all slave devices together.
36 REFIN
Voltage Error-Amplifier Reference Input. For master-mode or single-phase operation, connect REFIN to
PHASE/REFO through a resistor-divider to set the output voltage from 0 to 3.3V. To use an external
reference, connect REFIN to the system reference voltage, and use an RC network at REFIN to
implement soft-start if the external reference does not provide this function. Connect REFIN to GND for
slave mode operation.
37 P H AS E /RE FO
Phase Selection Input/Reference Voltage Output. For single-phase or master-mode operation, the 3.3V
output with 1% accuracy can be used as a reference voltage. For multiphase operation, connect
PHASE/REFO of each slave device to the center tap of a resistor-divider from the master AVL to GND.
The resistor values are selected to set phase delay between phases. The PWM cycle starts 60ns after
the rising edge of V
FREQ
crosses V
PHASE
.
38 COMP
Compensation and Output of the Voltage-Error Amplifier. Connect a Type II compensation network at
COMP. COMP is internally pulled to GND in shutdown. In multiphase applications, connect COMP of
the master and all slave devices together.
39 RS+
Positive Input of the Output-Voltage Remote Sense. For master-mode or single-phase operation,
connect RS+ to the output-voltage sense point at the load. Connect RS+ to AVL (slave) for slave mode
operation.
40 RS-
Negative Input of the Output-Voltage Remote Sense. For master-mode or single-phase operation,
connect RS- to the remote ground at the load. Connect RS- to AVL (slave) for slave mode operation.
— GND_EP Ground Exposed Paddle. Connect GND_EP to GND.
— IN_EP Input Exposed Paddle. Connect IN_EP to IN.
— LX_EP LX Exposed Paddle. Connect LX_EP to LX.