Data Sheet ADuM4160
Rev. D | Page 5 of 16
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 4.
Parameter Symbol Value Unit Conditions
Rated Dielectric Insulation Voltage 5000 V rms 1 minute duration
Minimum External Air Gap (Clearance) L(I01) 8.0 min mm
Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) RW-16 Package L(I02) 7.7 min mm
Measured from input terminals to output terminals,
shortest distance path along body
Minimum External Tracking (Creepage) RI-16 Package L(I02) 8.3 min mm
Measured from input terminals to output terminals,
shortest distance path along body
Minimum Internal Gap (Internal Clearance) 0.017 min mm Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
protective circuits. The * marking on packages denotes DIN V VDE V 0884-10 approval.
Table 5.
Description Conditions Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms I to IV
For Rated Mains Voltage ≤ 300 V rms I to III
For Rated Mains Voltage ≤ 400 V rms I to II
Climatic Classification 40/105/21
Pollution Degree per DIN VDE 0110, Table 1 2
Maximum Working Insulation Voltage V
IORM
846 V peak
Input-to-Output Test Voltage, Method b1
V
IORM
× 1.875 = V
PR
, 100% production test, t
m
= 1 sec,
partial discharge < 5 pC
V
PR
1590 V peak
Input-to-Output Test Voltage, Method a V
IORM
× 1.6 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC V
PR
After Environmental Tests Subgroup 1 1375 V peak
After Input and/or Safety Test Subgroup 2
and Subgroup 3
V
IORM
× 1.2 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC 1018 V peak
Highest Allowable Overvoltage Transient overvoltage, t
TR
= 10 seconds V
TR
6000 V peak
Safety-Limiting Values
Maximum value allowed in the event of a failure
(see Figure 2)
Case Temperature T
S
150 °C
Side 1 + Side 2 Current I
S1
550 mA
Insulation Resistance at T
S
V
IO
= 500 V R
S
>10
9
Ω
0
100
200
300
400
500
600
0 50 100 150 200
AMBIENT TEMPERATURE (°C)
SAFE OPERATING V
DD1
CURRENT (mA)
0
8171-002
Figure 2. Thermal Derating Curve, Dependence of Safety-Limiting Values with Case Temperature per DIN V VDE V 0884-10
ADuM4160 Data Sheet
Rev. D | Page 6 of 16
RECOMMENDED OPERATING CONDITIONS
Table 6.
Parameter Symbol Min Max Unit
Operating Temperature T
A
−40 +105 °C
Supply Voltages
1
V
BUS1
, V
BUS2
3.1 5.5 V
Input Signal Rise and Fall Times 1.0 ms
1
All voltages are relative to their respective ground. See the section for information on immunity to external magnetic
fields.
DC Correctness and Magnetic Field Immunity
Data Sheet ADuM4160
Rev. D | Page 7 of 16
ABSOLUTE MAXIMUM RATINGS
Ambient temperature = 25°C, unless otherwise noted.
Table 7.
Parameter Rating
Storage Temperature (T
ST
) −65°C to +150°C
Ambient Operating Temperature (T
A
) −40°C to +105°C
Supply Voltages (V
BUS1
, V
BUS2
, V
DD1
,
V
DD2
)
1
−0.5 V to +6.5 V
Upstream Input Voltage
(V
UD+
,V
UD−
, V
SPU
)
1, 2
−0.5 V to V
DD1
+ 0.5 V
Downstream Input Voltage
(V
DD+
, V
DD−
, V
SPD
, V
PIN
)
1, 2
−0.5 V to V
DD2
+ 0.5 V
Average Output Current per Pin
3
Side 1 (I
O1
) −10 mA to +10 mA
Side 2 (I
O2
) −10 mA to +10 mA
Common-Mode Transients
4
−100 kV/μs to +100 kV/μs
1
All voltages are relative to their respective ground.
2
V
DDI
, V
BUS1
, and V
DD2
, V
BUS2
refer to the supply voltages on the upstream and
downstream sides of the coupler, respectively.
3
See Figure 2 for maximum rated current values for various temperatures.
4
Refers to common-mode transients across the insulation barrier. Common-
mode transients exceeding the absolute maximum ratings may cause latch-up
or permanent damage.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Table 8. Maximum Continuous Working Voltage
1
Parameter Max Unit Constraint
AC Voltage, Bipolar
Waveform
565 V peak
50-year minimum
lifetime
AC Voltage, Unipolar
Waveform
Basic Insulation 848 V peak
Maximum approved
working voltage per
IEC 60950-1
Reinforced Insulation 846 V peak
Maximum approved
working voltage per
VDE 0884-10
DC Voltage
Basic Insulation 848 V peak
Maximum approved
working voltage per
IEC 60950-1
Reinforced Insulation 846 V peak
Maximum approved
working voltage per
VDE 0884-10
1
Refers to continuous voltage magnitude imposed across the isolation
barrier. See the Insulation Lifetime section for more information.