HCPL-0723-060E

4
Device Selection Guide
8-Pin DIP (300 mil) Small Outline SO-8
HCPL-7723 HCPL-0723
Ordering Information
HCPL-0723 and HCPL-7723 are UL Recognized with 3750 Vrms for 1 minute per UL1577.
Option
Part RoHS non RoHS Surface Gull Tape UL 5000 Vrms/ IEC/EN/DIN
Number Compliant Compliant Package Mount Wing & Reel 1 Minute rating EN 60747-5-5 Quantity
-000E no option 300 mil DIP-8 50 per tube
-300E -300 X X 50 per tube
-500E -500 X X X 1000 per reel
-020E -020 X 50 per tube
HCPL-7723
-320E -320 X X X 50 per tube
-520E -520 X X X X 1000 per reel
-060E -060 X 50 per tube
-360E -360 X X X 50 per tube
-560E -560 X X X X 1000 per reel
-000E no option SO-8 X 100 per tube
HCPL-0723
-500E -500 X X 1500 per reel
-060E -060 X X 100 per tube
-560E -560 X X X 1500 per reel
To order, choose a part number from the part number column and combine with the desired option from the option
column to form an order entry.
Example 1:
HCPL-7723-560E to order product of Gull Wing Surface Mount package in Tape and Reel packaging with IEC/EN/DIN
EN 60747-5-5 Safety Approval and RoHS compliant.
Example 2:
HCPL-0723 to order product of Small Outline SO-8 package in Tube packaging and non RoHS compliant.
Option datasheets are available. Contact your Avago sales representative or authorized distributor for information.
Remarks: The notation ‘#XXX’ is used for existing products, while (new) products launched since July 15, 2001 and
RoHS compliant will use ‘–XXXE.
5
Regulatory Information
The HCPL-7723/0723 have been approved by the following organizations:
UL
Recognized under UL1577, component recognition program, File E55361.
CSA
Approved under CSA Component Acceptance Notice #5, File CA88324.
IEC/EN/DIN EN 60747-5-5
Approved with Maximum Working Insulation Voltage:
V
iorm
= 567 V
peak
for HCPL-0723,
V
iorm
= 630 V
peak
for HCPL-7723
Solder Reow Prole
Recommended reow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used.
Insulation and Safety Related Specications
Value
Parameter Symbol 7723 0723 Units Conditions
Minimum External Air Gap L(I01) 7.1 4.9 mm Measured from input terminals to output
(Clearance) terminals, shortest distance through air.
Minimum External Tracking L(I02) 7.4 4.8 mm Measured from input terminals to output
(Creepage) terminals, shortest distance path along body.
Minimum Internal Plastic Gap 0.08 0.08 mm Insulation thickness between emitter and
(Internal Clearance) detector; also known as distance through
insulation.
Tracking Resistance CTI ≥ 175 ≥ 175 Volts DIN IEC 112/VDE 0303 Part 1
(Comparative Tracking Index)
Isolation Group IIIa IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
6
All Avago data sheets report the creepage and clearance
inherent to the optocoupler component itself. These
dimensions are needed as a starting point for the
equipment designer when determining the circuit insula-
tion requirements. However, once mounted on a printed
circuit board, minimum creepage and clearance require-
ments must be met as specied for individual equipment
standards. For creepage, the shortest distance path along
the surface of a printed circuit board between the solder
llets of the input and output leads must be considered.
There are recommended techniques such as grooves
and ribs, which may be used on a printed circuit board
to achieve desired creepage and clearances. Creepage
and clearance distances will also change depending
on factors such as pollution degree and insulation
level.
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics (Option 060)
Description Symbol
Characteristic
UnitHCPL-7723 HCPL-0723
Installation classication per DIN VDE 0110, Table 1
for rated mains voltage 150 V
rms
I – IV I – IV
for rated mains voltage 300 V
rms
I – III I – III
for rated mains voltage 600 V
rms
I – IV I – III
Climatic Classication 55/85/21 55/85/21
Pollution Degree (DIN VDE 0110/39) 2 2
Maximum Working Insulation Voltage V
IORM
630 567 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
=1 sec,
Partial discharge < 5 pC
V
PR
1181 1063 V
peak
Input to Output Test Voltage, Method a*
V
IORM
x 1.6 = V
PR
, Type and Sample Test, t
m
=10 sec, Partial discharge < 5 pC V
PR
1008 907 V
peak
Highest Allowable Overvoltage (Transient Overvoltage t
ini
= 60 sec) V
IOTM
8000 6000 V
peak
Safety-limiting values – maximum values allowed in the event of a failure
Case Temperature T
S
175 150
°C
Input Current I
S, INPUT
230 150 mA
Output Power P
S, OUTPUT
600 600 mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
10
9
10
9
*Refer to the optocoupler section of the Isolation and Control Component Designer’s Catalog, under Product Safety Regulations section IEC/EN/
DIN EN 60747-5-5, for a detailed description of Method a and Method b partial discharge test proles.

HCPL-0723-060E

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
High Speed Optocouplers 50MBd 1Ch 150mA
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union