Data Sheet ADRF5040
Rev. A | Page 3 of 14
SPECIFICATIONS
ELECTRICAL SPECIFICATIONS
V
DD
= 3.3 V, V
SS
= −3.3 V, V
1
and V
2
= 0 V or V
DD
, T
A
= 25°C, 50 Ω system, unless otherwise noted.
Table 1.
Parameter Test Conditions/Comments Min Typ Max Unit
INSERTION LOSS
9 kHz to 4.0 GHz 0.7 dB
9 kHz to 8.0 GHz 0.8 dB
9 kHz to 10.0 GHz 1.1 dB
9 kHz to 12.0 GHz 2 dB
ISOLATION, RFC TO RF1 TO RF4 (WORST CASE)
9 kHz to 4.0 GHz 44 dB
9 kHz to 8.0 GHz 34 dB
9 kHz to 10.0 GHz 29.2 dB
9 kHz to 12.0 GHz 20 dB
RETURN LOSS
On State 9 kHz to 4.0 GHz 21 dB
9 kHz to 8.0 GHz 19 dB
9 kHz to 12.0 GHz 8 dB
Off State 9 kHz to 4.0 GHz 25 dB
9 kHz to 8.0 GHz 18.6 dB
9 kHz to 10.0 GHz 15.5 dB
9 kHz to 12.0 GHz 14.5 dB
RADIO FREQUENCY (RF) SETTLING TIME
50% V
1
/V
2
to 0.05 dB margin of final RF
OUT
9 µs
50% V
1
/V
2
to 0.1 dB margin of final RF
OUT
7 µs
SWITCHING SPEED
t
RISE
/t
FAL L
10% to 90% RF
OUT
1.3 µs
ON
OFF
1
2
INPUT POWER 9 kHz to 12.0 GHz
1 dB Compression (P1dB) 37 dBm
0.1 dB Compression (P0.1dB) 34 dBm
INPUT THIRD-ORDER INTERCEPT (IIP3) Two-tone input power = 14 dBm at each tone
1 MHz to 2.0 GHz 62 dBm
1 MHz to 8.0 GHz 58 dBm
RECOMMENDED OPERATING CONDITIONS
Positive Supply Voltage (V
DD
) 3.0 3.6 V
Negative Supply Voltage (V
SS
) −3.6 −3.0 V
Control Voltage (V
1
, V
2
) Range 0 V
DD
V
RF Input Power V
DD
= 3.3 V, V
SS
= −3.3 V, T
A
= 85°C, frequency = 2 GHz
Through Path 33 dBm
Termination Path 27 dBm
Hot Switch Power Level V
DD
= 3.3 V, T
A
= 85°C, frequency = 2 GHz 27 dBm
Case Temperature Range (T
CASE