M41T11 DC and AC parameters
Doc ID 6103 Rev 10 19/30
5 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC characteristic
tables are derived from tests performed under the measurement conditions listed in Ta bl e 5 :
Operating and AC measurement conditions. Designers should check that the operating
conditions in their projects match the measurement conditions when using the quoted
parameters.
Figure 14. AC testing input/output waveform
Table 5. Operating and AC measurement conditions
(1)
1. Output Hi-Z is defined as the point where data is no longer driven.
Parameter M41T11 Unit
Supply voltage (V
CC
) 2.0 to 5.5
(2)
2. Supply voltage for SOH28 is 3.3 V to 5.5 V.
V
Ambient operating temperature (T
A
) –40 to 85 °C
Load capacitance (C
L
) 100 pF
Input rise and fall times 50 ns
Input pulse voltages 0.2V
CC
to 0.8V
CC
V
Input and output timing ref. voltages 0.3V
CC
to 0.7V
CC
V
AI02568
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC
DC and AC parameters M41T11
20/30 Doc ID 6103 Rev 10
Table 6. Capacitance
Symbol Parameter
(1)(2)
1. Effective capacitance measured with power supply at 5 V; sampled only, not 100% tested.
2. At 25°C, f = 1 MHz.
Min Max Unit
C
IN
Input capacitance (SCL) 7 pF
C
OUT
(3)
3. Outputs deselected.
Output capacitance (SDA, FT/OUT) 10 pF
t
LP
Low-pass filter input time constant (SDA and SCL) 250 1000 ns
Table 7. DC characteristics
Symbol Parameter Test Condition
(1)
1. Valid for ambient operating temperature: T
A
= –40 to 85°C; V
CC
= 2.0 to 5.5 V (except where noted).
Min Typ Max Unit
I
LI
Input leakage current 0V V
IN
V
CC
±1 µA
I
LO
Output leakage current 0V V
OUT
V
CC
±1 µA
I
CC1
Supply current Switch frequency = 100 kHz 300 µA
I
CC2
Supply current (standby) SCL, SDA = V
CC
– 0.3 V 70 µA
V
IL
Input low voltage –0.3 0.3V
CC
V
V
IH
Input high voltage 0.7V
CC
V
CC
+ 0.5 V
V
OL
Output low voltage I
OL
= 3 mA 0.4 V
Pull-up supply voltage
(open drain)
FT/OUT 5.5 V
V
BAT
(2)
2. STMicroelectronics recommends the RAYOVAC BR1225 or BR1632 (or equivalent) as the battery supply.
Battery supply voltage 2.5
(3)
3. After switchover (V
SO
), V
BAT
(min) can be 2.0 V for crystal with R
S
= 40 KΩ.
33.5
(4)
4. For rechargeable back-up, V
BAT
(max) may be considered V
CC
.
V
I
BAT
Battery supply current
T
A
= 25°C, V
CC
= 0 V,
oscillator ON, V
BAT
= 3 V
0.8 1 µA
Table 8. Crystal electrical characteristics
Symbol Parameter
(1)(2)(3)
1. These values are externally supplied if using the SO8 package. STMicroelectronics recommends the KDS
DT-38: 1TA/1TC252E127, Tuning Fork Type (thru-hole) or the DMX-26S: 1TJS125FH2A212, (SMD)
quartz crystal for industrial temperature operations. Please refer to the KDS website for further information
on this crystal type.
2. Load capacitors are integrated within the M41T11. Circuit board layout considerations for the 32.768 kHz
crystal of minimum trace lengths and isolation from RF generating signals should be taken into account.
3. All SNAPHAT
®
battery:crystal tops meet these specifications.
Min Typ Max Unit
f
O
Resonant frequency 32.768 kHz
R
S
Series resistance 60
(4)
4. ESR (max) = 110 kΩ for V
CC
or V
BAT
> 2.5 V.
kΩ
C
L
Load capacitance 12.5 pF
M41T11 DC and AC parameters
Doc ID 6103 Rev 10 21/30
Figure 15. Power down/up mode AC waveforms
Table 9. Power down/up AC characteristics
Symbol Parameter
(1)(2)
1. Valid for ambient operating temperature: T
A
= –40 to 85°C; V
CC
= 2.0 to 5.5 V (except where noted).
2. V
CC
fall time should not exceed 5 mV/µs.
Min Max Unit
t
PD
SCL and SDA at V
IH
before power down 0 ns
t
REC
SCL and SDA at V
IH
after power up 10 µs
Table 10. Power down/up trip points DC characteristics
Symbol Parameter
(1)(2)
1. Valid for ambient operating temperature: T
A
= –40 to 85°C; V
CC
= 2.0 to 5.5 V (except where noted).
2. All voltages referenced to V
SS
.
Min Typ Max
(3)
3. In 3.3 V application, if initial battery voltage is 3.4 V, it may be necessary to reduce battery voltage (i.e.,
through wave soldering the battery) in order to avoid inadvertent switchover/deselection for V
CC
– 10%
operation.
Unit
V
SO
(4)
4. Switchover and deselect point.
Battery backup switchover voltage V
BAT
– 0.80 V
BAT
– 0.50 V
BAT
– 0.30 V
AI00596
V
CC
tREC
tPD
V
SO
SDA
SCL
DON'T CARE

M41T11M6F

Mfr. #:
Manufacturer:
STMicroelectronics
Description:
Real Time Clock Serial 512 (64x8)
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet