Symbol Inches Millimeters Notes
Min Max Min Max
A 0.115 0.150 2.92 3.81
φb
--- 0.021 --- 0.53 2, 5
φb2
0.016 0.019 0.41 0.48 2, 5
φD
0.209 0.230 5.31 5.84
φD
1
0.178 0.195 4.52 4.95
e 0.100 BSC 2.54 BSC 3
e
1
0.050 BSC 1.27 BSC 3
F --- 0.030 --- 0.76
j 0.036 0.046 0.91 1.17
k 0.028 0.048 0.71 1.22 4
L 0.500 --- 12.70 --- 2
L
1
--- 0.050 --- 1.27 2
L
2
0.250 --- 6.35 ---
α 45° BSC 45° BSC
NOTES:
1. The US government preferred system of measurement is the metric SI system. However, this item was originally
designed using inch-pound units of measurement. In the event of conflict between the metric and inch-pound units,
the inch-pound units shall take precedence.
2. (Three leads) φb
2
applies between L
1
and L
2
. φb applies between L
2
and 0.5 inch (12.70 mm) from seating plane.
Diameter is uncontrolled in L
1
and beyond 0.5 inch (12.70 mm) from seating plane.
3. Leads having maximum diameter 0.019 inch (0.48 mm) measured in gauging plane 0.054 inch (1.4 mm) + 0.001 inch
(0.03 mm) - 0.000 inch (0.00 mm) below the seating plane of the device are within 0.007 inch (0.18 mm) of their true
positions relative to a maximum-width tab.
4. Measured from maximum diameter of the actual device.
5. All leads: Increase maximum limit by 0.003 inch (0.08 mm) when hot solder dip finish is applied.
FIGURE 2. Case outline Y (3-lead metal can) Continued.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-87571
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
REVISION LEVEL
H
SHEET
11
DSCC FORM 2234
APR 97
Device types 01, 02, 03, 04 01, 02, 03, 04, 05
Case outlines X Y
Terminal number Terminal symbol
1
+ +
2
3 --- NC
NC = No connect
FIGURE 3. Terminal connections.
NOTE: V
S
across device must remain constant or PSRR error must be included.
FIGURE 4. One temperature trim.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-87571
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
REVISION LEVEL
H
SHEET
12
DSCC FORM 2234
APR 97
4. VERIFICATION
4.1 Sampling and inspection. For device classes Q and V, sampling and inspection procedures shall be in accordance with
MIL-PRF-38535 or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan
shall not affect the form, fit, or function as described herein. For device class M, sampling and inspection procedures shall be in
accordance with MIL-PRF-38535, appendix A.
4.2 Screening. For device classes Q and V, screening shall be in accordance with MIL-PRF-38535, and shall be conducted
on all devices prior to qualification and technology conformance inspection. For device class M, screening shall be in
accordance with method 5004 of MIL-STD-883, and shall be conducted on all devices prior to quality conformance inspection.
4.2.1 Additional criteria for device class M.
a. Burn-in test, method 1015 of MIL-STD-883.
(1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision
level control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in
method 1015.
(2) T
A
= +125°C, minimum.
b. Interim and final electrical test parameters shall be as specified in table IIA herein.
4.2.2 Additional criteria for device classes Q and V.
a. The burn-in test duration, test condition and test temperature, or approved alternatives shall be as specified in the
device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be maintained under
document revision level control of the device manufacturer's Technology Review Board (TRB) in accordance with
MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in
method 1015 of MIL-STD-883.
b. Interim and final electrical test parameters shall be as specified in table IIA herein.
c. Additional screening for device class V beyond the requirements of device class Q shall be as specified in
MIL-PRF-38535, appendix B.
4.3 Qualification inspection for device classes Q and V. Qualification inspection for device classes Q and V shall be in
accordance with MIL-PRF-38535. Inspections to be performed shall be those specified in MIL-PRF-38535 and herein for groups
A, B, C, D, and E inspections (see 4.4.1 through 4.4.4).
4.4 Conformance inspection. Technology conformance inspection for classes Q and V shall be in accordance with
MIL-PRF-38535 including groups A, B, C, D, and E inspections and as specified. Quality conformance inspection for device
class M shall be in accordance with MIL-PRF-38535, appendix A and as specified herein. Inspections to be performed for
device class M shall be those specified in method 5005 of MIL-STD-883 and herein for groups A, B, C, D, and E inspections
(see 4.4.1 through 4.4.4).
4.4.1 Group A inspection.
a. Tests shall be as specified in table IIA herein.
b. Subgroups 4, 5, 6, 7, 8, 9, 10, and 11 in table I, method 5005 of MIL-STD-883 shall be omitted.
c. Optional subgroup 12 is used for grading and part selection at +25°C, it is not included in PDA.

5962-8757102XA

Mfr. #:
Manufacturer:
Analog Devices Inc.
Description:
Board Mount Temperature Sensors Two Terminal IC Temp Transducer
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union