STANDARD
SIZE
A
5962-87571
COLUMBUS, OHIO 43218-3990
REVISION LEVEL
H
SHEET
7
DSCC FORM 2234
APR 97
TABLE I. Electrical performance characteristics – Continued.
Test
Symbol
Conditions 1/ 2/
-55°C ≤ T
A
≤+125°C
V
S
= +5 V
unless otherwise specified
Group A
subgroups
Device
type
Limits
Unit
Min Max
Power supply rejection ratio
PSRR
+4 V ≤ V
S
≤ +5 V 3/ 5/
1 All 1
°C/V
+5 V ≤ V
S
≤ +15 V 3/ 5/
0.4
+15 V ≤ V
S
≤ +30 V 3/ 5/
0.2
Power supply voltage range
V
S
3/ 5/ 1 All +4 V
+30
1/ Device types 03 and 04 supplied to this drawing have been characterized through all levels P, L, R of irradiation.
Device type 05 supplied to this drawing has been characterized through all levels P and L of irradiation.
However, device types 03 and 04 are only tested at the “R” and device type 05 is only tested at the “L” level.
Pre and Post irradiation values are identical unless otherwise specified in Table I.
2/ Device types 03 and 04 may be dose rate sensitive in a space environment and may demonstrate enhanced low dose
rate effects. Radiation end point limits for the noted parameters are guaranteed only for the conditions specified in
MIL-STD-883, method 1019, condition A for device types 03 and 04 and condition D for device type 05.
3/ This parameter is not tested post-irradiation.
4/ See figure 4.
5/ Guaranteed if not tested.
6/ For device types 02, 03, 04, and 05 class V maximum temperature = +125°C.