1Description
IEC 62061
SILCL
Safety relay for emergency stop, safety door and
light grid monitoring
PSR-MS60
© PHOENIX CONTACT
Data sheet
Intended Use
The PSR-MS60 safety relay can be used to monitor two-
channel signal generators, e.g.,emergency stop buttons,
safety door locking mechanisms, and light grids, as well as
to control actuators.
The safety relay is equipped with two single-channel en-
abling current paths that drop out without delay according to
stop category 0 and EN60204-1.
The enabling current paths are controlled automatically
once the sensor circuit has been closed.
Features
Safety relay for emergency stop, safety door, and light
grid monitoring
Suitable up to category4, PLe (ENISO13849-1),
SILCL3 (EN62061)
1 two-channel sensor circuit
2 undelayed single-channel enabling current paths
Fixed screw connection
–6.8mm housing width
WARNING: Risk of electric shock
Observe the safety instructions in the corresponding section!
Make sure you always use the latest documentation.
It can be downloaded from the product at phoenixcontact.net/products.
This document meets the same requirements as the original operating instructions in terms of contents and is
valid for all products listed in the “Ordering data” section.
106171_en_02
2015-08-21
PSR-MS60
106171_en_02 PHOENIX CONTACT 2
2Table of contents
1 Description .............................................................................................................................. 1
2 Table of contents ..................................................................................................................... 2
3 Ordering data .......................................................................................................................... 3
4 Technical data ......................................................................................................................... 3
5 Safety notes............................................................................................................................. 6
6 Basic circuit diagram ............................................................................................................... 7
7 Derating................................................................................................................................... 7
7.1 Vertical or horizontal mounting position ..................................................................................... 7
8 Load curve............................................................................................................................... 7
8.1 Ohmic load ........................................................................................................................ 7
9 Function/time diagrams ........................................................................................................... 7
10 Operating and indication elements .......................................................................................... 8
10.1 Connection versions............................................................................................................. 8
10.2 Connection assignment......................................................................................................... 8
11 Mounting and connection ........................................................................................................ 9
12 Startup..................................................................................................................................... 9
13 Calculating the power dissipation .......................................................................................... 10
14 Diagnostics............................................................................................................................ 11
14.1 General states .................................................................................................................. 11
14.2 Error Messages................................................................................................................. 11
15 Application examples ............................................................................................................ 12
15.1 Light grid monitoring/automatic start....................................................................................... 12
15.2 Two-channel control via LPSDO module ................................................................................. 12
15.3 Single-channel control via failsafe controller ............................................................................. 13
16 Revision history ..................................................................................................................... 14
PSR-MS60
106171_en_02 PHOENIX CONTACT 3
Description Type Order No. Pcs. / Pkt.
Safety relay for emergency stop, safety doors, and light grids up to SIL3,
SILCL3, Cat.4, PLe, 2-channel operation, automatic start, 2 enabling cur-
rent paths (1-channel), U
S
=24VDC, fixed screw terminal block
PSR-MS60-2NO-24DC-SC 2904958 1
3Ordering data
4 Technical data
Hardware/firmware version
HW/FW 00/-- (The technical data and safety characteristics are valid as of the specified
HW/FW version.)
Input data
Rated control supply voltage U
S
24 V DC -15 % / +10 %
Rated control supply current I
S
typ. 40 mA
Input voltage range "0"-signal 0 V DC ... 5 V DC (for safe off)
Typical inrush current 4.5 A (t=120s at U
s
)
< 20 mA (with U
s
/I
x
to S12)
< 20 mA (with U
s
/I
x
to S22)
Current consumption < 5 mA (with U
s
/I
x
to S12)
< 5 mA (with U
s
/I
x
to S22)
Power consumption at U
S
typ. 0.96 W
Voltage at input/start and feedback circuit 24 V DC -15 % / +10 %
Filter time 1 ms (at A1 in the event of voltage dips at U
s
)
max. 1.5 ms (Test pulse duration)
min. 7.5 ms (Test pulse rate)
Test pulse rate=5xTest pulse width
Max. permissible overall conductor resistance
(Input and reset circuit at U
S
)
150
Typical response time at U
s
< 175 ms
Typical starting time with U
s
< 250 ms (when controlled via A1)
Typical release time with U
s
< 20 ms (when controlled via A1 or S12 and S22.)
Recovery time < 500 ms
Maximum switching frequency 0.5 Hz
Operating voltage display 1 x green LED
Status display 2 x green LEDs
Protective circuit Surge protection Suppressor diode
Reverse polarity protection for rated control supply voltage
Output data
Contact type 2 enabling current paths
Contact material AgSnO
2
Minimum switching voltage 10 V AC/DC
Maximum switching voltage 250 V AC/DC
Limiting continuous current 6 A (N/O contact)
Maximum inrush current 6 A
Inrush current, minimum 3 mA
Sq. Total current 72 A
2
(see to derating)
Switching capacity min. 30 mW
Mechanical service life 10 x 10
6
cycles
Output fuse 6 A gL/gG (N/O contact)
4 A gL/gG (for low-demand applications)

2904958