RBO40-40G / RBO40-40T
4/10
PRODUCT DESCRIPTION
1
2
3
The RBO has 3 functions integrated on the same
chip.
D1 : “Diode function” in order to protect against
reversed battery operation.
T2 : “Transil function” in order to protect against
positive surge generated by electric systems
(ignition, relay. ...).
T1 : Protection for motor drive application
(See below).
BASIC APPLICATION
* The monolithic multi-function protection
(RBO) has been developed to protect sen
-
sitive semiconductors in car electronic
modules against both overvoltage and
battery reverse.
* In addition, the RBO circuit prevents
overvoltages generated by the module from
affecting the car supply network.
MOTOR DRIVER APPLICATION
D1
T1
T2
BATTERY
RBO
DEVICE MOTOR CONTROL
MOTOR
Filter
In this application, one half of the motor drive circuit is supplied through the “RBO” and is thus protected
as per its basic function application.
The second part is connected directly to the “car supply network” and is protected as follows :
- For positive surges : T2 (clamping phase) and D1 in forward-biased.
- For negative surges : T1 (clamping phase) and T2 in forward-biased.
RBO40-40G / RBO40-40T
5/10
- Input (1) : Pin 1
- Output (3) : Pin 3
- Gnd (2) : Connected to base Tab
Marking : Logo, date code, RBO40-40G
PINOUT configuration in D
2
PAK :
D1
T1
T2
TAB
D1
T1
T2
(TAB)
- Input (1) : Pin 1
- Output (3) : Pin 3
- GND (2) : Connected to base Tab
Marking : Logo, date code, RBO40-40T
PINOUT configuration in TO220AB :
RBO40-40G / RBO40-40T
6/10
LOAD DUMP TEST GENERATOR CIRCUIT (SCHAFFNER NSG 506 C). Issued from ISO / DTR 7637.
U(V)
t
0
Vbat
90%
Vs
10%
t
tr
offset
10% / 13.5V
Open circuit (voltage curve)
(pulse test n°5)
Corresponding current wave with D.U.T.
Ipp
Ipp/2
0
I
tp = 40ms
t
Impulse N°5
Vs (V)
66.5
Vbat (V)
13.5
Ri ()
2
t (ms)
200 (*)
tr (ms)
<10
Number
5
60s between each pulse
(*) Generator setting
1) With open circuit (generator is in open circuit):
- calibrate Vs
2) With short circuit (generator is in short circuit):
- calibrate Ri (Ri = 2)
3) With D.U.T.
- calibrate tp (tp = 40ms @ Ipp/2)
typ. Vpp
V
Bat
20ms/div.
10.0V/div.
Typical Voltage curve (open circuit)
typ. VCL
Ipp
20ms/div.
5.0V/div.
20ms/div.
3A/div.
Typical Voltage and Current curve with D.U.T.
CALIBRATION METHOD FOR SCHAFFNER NSG 506 C