RBO40-40G / RBO40-40T
7/10
1
2 5 10 20 50 100
0.1
0.2
0.5
1.0
2.0
5.0
10.0
Transil T1
Transil T2
t
p
(ms)
Ppp(kW)
Fig. 1 : Peak pulse power versus exponential
pulse duration (Tj initial = 85°C).
V (V)CL
1
2 5 10 20 50 100 200 500
25
30
35
40
45
50
55
t
p=1ms
tp = 20µs
I
p
p
(
A)
Fig. 2-2 : Clamping voltage versus peak pulse
current (Tj initial = 85°C).
Exponential waveform tp = 1 ms and tp = 20 µs
(TRANSIL T1).
0.1
0.2 0.5 1 2 5 10 20 50 100
30.0
32.5
35.0
37.5
40.0
42.5
45.0
tp = 40ms
tp = 1ms
Ipp(A)
V (V)CL
Fig. 2-1 : Clamping voltage versus peak pulse
current (Tj initial = 85°C).
Exponential waveform tp = 40 ms and tp=1ms
(TRANSIL T2).
0
25 50 75 100 125 150 175
0.00
0.20
0.40
0.60
0.80
1.00
1.20
Tj initial (°C)
Ppp[Tj]/Ppp[Tj initial=85°C]
Fig. 3 : Relative variation of peak pulse power
versus junction temperature.