IDT
®
Programmable Timing Control Hub
TM
for Mobile P4
TM
Systems 0930A—04/13/10
954226
Programmable Timing Control Hub
TM
for Mobile P4
TM
Systems
17
Electrical Characteristics - SATA/PCIEX/LCDCLK_SS@100M 0.7V Current Mode Differential Pair
PARAMETER SYMBOL CONDITIONS* MIN TYP MAX UNITS Notes
Current Source Output
Impedance
Zo VO = Vx 3000
Ω
1
Voltage High VHigh 660 850 mV 1,3
Voltage Low VLow -150 150 mV 1,3
Max Voltage Vovs 1150 mV 1
Min Volta
e Vuds -300 mV 1
Crossing Voltage (abs) Vx(abs) 250 550 mV 1
Crossing Voltage (var) d-Vx Variation of crossing over all edges 140 mV 1
Long Accuracy ppm see Tperiod min-max values -300 300 ppm 1,2
100.00MHz nominal 9.9970 10.0030 ns 2
100.00MHz spread 9.9970 10.0533 ns 2
Absolute min period Tabsmin 100.00MHz nominal/spread 9.8720 ns 1,2
Rise Time tr VOL = 0.175V, VOH = 0.525V 175 700 ps 1
Fall Time tf VOH = 0.525V VOL = 0.175V 175 700 ps 1
Rise Time Variation d-tr VOL = 0.175V, VOH = 0.525V 125 ps 1
Fall Time Variation d-tf VOH = 0.525V VOL = 0.175V 125 ps 1
Rise/Fall Matching trfm 20 % 1
Duty Cycle dt3 Measurement from differential wavefrom 45 55 % 1
Skew tsk3 VT = 50% 250 ps 1
Jitter, Cycle to cycle tjcyc-cyc Measurement from differential wavefrom 125 ps 1
*T
A
= 0 - 70°C; V
DD
= 3.3 V +/-5%; C
L
=2pF, R
S
=33.2
Ω
, R
P
=49.9
Ω
Β
I
REF
= 475
Ω
1
Guaranteed by design and characterization, not 100% tested in production.
2
All Long Term Accuracy and Clock Period specifications are guaranteed assuming that REFOUT is at 14.31818MHz
3
I
REF
= V
DD
/(3xR
R
). For R
R
= 475
Ω
(1%), I
REF
= 2.32mA. I
OH
= 6 x I
REF
and V
OH
= 0.7V @ Z
=50
Ω
.
Statistical measurement on single
ended signal
Measurement on single ended signal
usin
absolute value.
Average period Tperiod
Electrical Characteristics - DOT_96MHz/LCDCLK_SS@96M 0.7V Current Mode Differential Pair
PARAMETER SYMBOL CONDITIONS* MIN TYP MAX UNITS Notes
Current Source Output
Impedance
Zo VO = Vx 3000
Ω
1
Voltage High VHigh 660 850 mV 1,3
Voltage Low VLow -150 150 mV 1,3
Max Voltage Vovs 1150 mV 1
Min Voltage Vuds -300 mV 1
Crossing Voltage (abs) Vx(abs) 250 550 mV 1
Crossing Voltage (var) d-Vcross Variation of crossing over all edges 140 mV 1
Long Accuracy ppm see Tperiod min-max values -100 100 ppm 1,2
Average period Tperiod
96.00MHz nominal 10.4135 10.4198 ns 2
Absolute min period Tabsmin 96.00MHz nominal 10.1635 ns 1,2
Rise Time tr VOL = 0.175V, VOH = 0.525V 175 700 ps 1
Fall Time tf VOH = 0.525V VOL = 0.175V 175 700 ps 1
Rise Time Variation d-tr VOL = 0.175V, VOH = 0.525V 125 ps 1
Fall Time Variation d-tf VOH = 0.525V VOL = 0.175V 125 ps 1
Rise/Fall Matching trfm 20 % 1
Duty Cycle dt3 Measurement from differential wavefrom 45 55 % 1
Jitter, Cycle to cycle tjcyc-cyc Measurement from differential wavefrom 250 ps 1
*T
A
= 0 - 70°C; V
DD
= 3.3 V +/-5%; C
L
=2pF, R
S
=33.2
Ω
, R
P
=49.9
Ω
Τ
I
REF
= 475
Ω
1
Guaranteed by design and characterization, not 100% tested in production.
2
All Long Term Accuracy and Clock Period specifications are guaranteed assuming that REFOUT is at 14.31818MHz
3
I
REF
= V
DD
/(3xR
R
). For R
R
= 475
Ω
(1%), I
REF
= 2.32mA. I
OH
= 6 x I
REF
and V
OH
= 0.7V @ Z
O
=50
Ω
.
Measurement on single ended signal
using absolute value.
Statistical measurement on single
ended signal