AD7401A
Rev. C | Page 6 of 20
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 3.
Parameter Symbol Value Unit Conditions
Input-to-Output Momentary Withstand Voltage V
ISO
5000 min V 1-minute duration
Minimum External Air Gap (Clearance) L(I01) 8.1 min mm
Measured from input terminals to output
terminals, shortest distance through air
Minimum External Tracking (Creepage) L(I02) 7.46 min mm
Measured from input terminals to output
terminals, shortest distance path along body
Minimum Internal Gap (Internal Clearance) 0.017 min mm Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table I)
REGULATORY INFORMATION
Table 4.
UL
1
CSA VDE
2
Recognized Under 1577
Component Recognition Program
1
Approved under CSA Component
Acceptance Notice #5A
Certified according to DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
2
5000 V rms Isolation Voltage
Reinforced insulation per
CSA 60950-1-03 and IEC 60950-1,
630 V rms maximum working
voltage
Reinforced insulation per DIN V VDE V 0884-10 (VDE V
0884-10):2006-12, 891 V peak
File E214100 File 205078 File 2471900-4880-0001
1
In accordance with UL 1577, each AD7401A is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 second (current leakage detection limit = 15 μA).
2
In accordance with DIN V VDE V 0884-10, each AD7401A is proof tested by applying an insulation test voltage ≥1671V peak for 1 sec (partial discharge detection limit = 5 pC).
AD7401A
Rev. C | Page 7 of 20
DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 INSULATION CHARACTERISTICS
This isolator is suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
means of protective circuits.
Table 5.
Description Symbol Characteristic Unit
INSTALLATION CLASSIFICATION PER DIN VDE 0110
For Rated Mains Voltage ≤ 300 V rms I to IV
For Rated Mains Voltage ≤ 450 V rms I to II
For Rated Mains Voltage ≤ 600 V rms I to II
CLIMATIC CLASSIFICATION 40/105/21
POLLUTION DEGREE (DIN VDE 0110, TABLE 1) 2
MAXIMUM WORKING INSULATION VOLTAGE V
IORM
891 V peak
INPUT-TO-OUTPUT TEST VOLTAGE, METHOD B1
V
IORM
× 1.875 = V
PR
, 100% Production Test, t
m
= 1 sec, Partial Discharge < 5 pC V
PR
1671 V peak
INPUT-TO-OUTPUT TEST VOLTAGE, METHOD A V
PR
After Environmental Test Subgroup 1 1426 V peak
V
IORM
× 1.6 = V
PR
, t
m
= 60 sec, Partial Discharge < 5 pC
After Input and/or Safety Test Subgroup 2/ Safety Test Subgroup 3 1069 V peak
V
IORM
× 1.2 = V
PR
, t
m
= 60 sec, Partial Discharge < 5 pC
HIGHEST ALLOWABLE OVERVOLTAGE (TRANSIENT OVERVOLTAGE, t
TR
= 10 sec) V
TR
6000 V peak
SAFETY-LIMITING VALUES (MAXIMUM VALUE ALLOWED IN THE EVENT OF A FAILURE, SEE Figure 4)
Case Temperature T
S
150 °C
Side 1 Current I
S1
265 mA
Side 2 Current I
S2
335 mA
INSULATION RESISTANCE AT T
S
, V
IO
= 500 V R
S
>10
9
Ω
CASE TEMPERATURE (°C)
SAFETY-LIMITING CURRENT (mA)
0
0
350
300
250
200
150
100
50
50 100 150 200
SIDE #1
SIDE #2
07332-004
Figure 4. Thermal Derating Curve, Dependence of Safety-Limiting Values
with Case Temperature per DIN V VDE V 0884-10
AD7401A
Rev. C | Page 8 of 20
ABSOLUTE MAXIMUM RATINGS
T
A
= 25°C, unless otherwise noted. All voltages are relative to
their respective ground.
Table 6.
Parameter Rating
V
DD1
to GND
1
−0.3 V to +6.5 V
V
DD2
to GND
2
−0.3 V to +6.5 V
Analog Input Voltage to GND
1
−0.3 V to V
DD1
+ 0.3 V
Digital Input Voltage to GND
2
−0.3 V to V
DD1
+ 0.5 V
Output Voltage to GND
2
−0.3 V to V
DD2
+ 0.3 V
Input Current to Any Pin Except Supplies
1
±10 mA
Operating Temperature Range −40°C to +125°C
Storage Temperature Range −65°C to +150°C
Junction Temperature 150°C
SOIC Package
θ
JA
Thermal Impedance
2
89.2°C/W
θ
JC
Thermal Impedance
2
55.6°C/W
Resistance (Input to Output), R
I-O
10
12
Ω
Capacitance (Input to Output), C
I-O
3
1.7 pF typ
Pb-Free Temperature, Soldering
Reflow 260°C
ESD 1.5 kV
1
Transient currents of up to 100 mA do not cause SCR to latch up.
2
EDEC 2S2P standard board.
3
f = 1 MHz.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Table 7. Maximum Continuous Working Voltage
1
Parameter Max Unit Constraint
AC Voltage, Bipolar
Waveform
565 V peak
50-year minimum
lifetime
AC Voltage, Unipolar
Waveform
891 V peak
Maximum CSA/VDE
approved working
voltage
DC Voltage 891 V
Maximum CSA/VDE
approved working
voltage
1
Refers to continuous voltage magnitude imposed across the isolation
barrier. See the Insulation Lifetime section for more details.
ESD CAUTION

AD7401AYRWZ-RL

Mfr. #:
Manufacturer:
Analog Devices Inc.
Description:
Analog to Digital Converters - ADC Isolated Modulator
Lifecycle:
New from this manufacturer.