M93C46, M93C56, M93C66, M93C76, M93C86 DC and AC parameters
Doc ID 4997 Rev 12 19/34
11 DC and AC parameters
This section summarizes the operating and measurement conditions, and the dc and ac
characteristics of the device. The parameters in the dc and ac characteristic tables that
follow are derived from tests performed under the measurement conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 9. Operating conditions (M93Cx6)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 4.5 5.5 V
T
A
Ambient operating temperature (device grade 6) –40 85 °C
Ambient operating temperature (device grade 3) –40 125 °C
Table 10. Operating conditions (M93Cx6-W)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 2.5 5.5 V
T
A
Ambient operating temperature (device grade 6) –40 85 °C
Ambient operating temperature (device grade 3) –40 125 °C
Table 11. Operating conditions (M93Cx6-R)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.8 5.5 V
T
A
Ambient operating temperature (device grade 6) –40 85 °C
Table 12. AC measurement conditions (M93Cx6)
(1)
1. Output Hi-Z is defined as the point where data out is no longer driven.
Symbol Parameter Min. Max. Unit
C
L
Load capacitance 100 pF
Input rise and fall times 50 ns
Input pulse voltages 0.4 V to 2.4 V V
Input timing reference voltages 1.0 V and 2.0 V V
Output timing reference voltages 0.8 V and 2.0 V V