CPC7582
4 www.clare.com R05
1.3 Absolute Maximum Ratings
Absolute maximum electrical ratings are at 25°C.
Absolute maximum ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at these or
any other conditions beyond those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to the absolute maximum ratings for
an extended period may degrade the device and affect its
reliability.
1.4 ESD Rating
1.5 General Conditions
Unless otherwise specified, minimum and maximum
values are production testing requirements.
Typical values are characteristic of the device at 25°C
and are the result of engineering evaluations. They are
provided for informational purposes only and are not
part of the manufacturing testing requirements.
Specifications cover the operating temperature range
T
A
= -40°C to +85°C. Also, unless otherwise specified
all testing is performed with V
DD
= +5V
dc
, logic low
input voltage is 0V
dc
and logic high input voltage is
+5V
dc
.
Parameter Minimum Maximum Unit
+5 V power supply (V
DD
)
-0.3 7 V
Battery Supply - -85 V
D
GND
to F
GND
separation
-5 +5 V
Logic input voltage -0.3
V
DD
+0.3
V
Logic input to switch output
isolation
-320V
Switch open-contact
isolation (SW1, SW2, SW3,
SW5, SW6)
-320V
Switch open-contact
isolation (SW4)
-465V
Operating relative humidity 5 95 %
Operating temperature -40 +110 °C
Storage temperature -40 +150 °C
ESD Rating (Human Body Model)
1000 V
CPC7582
R05 www.clare.com 5
1.6 Switch Specifications
1.6.1 Break Switches, SW1 and SW2
Parameter Conditions Symbol Minimum Typical Maximum Unit
Off-state leakage current
+25° C
V
SW
(differential) = -320 V to GND
V
SW
(differential) = +260 V to -60 V
I
SW
-
0.1
1 μA+85° C
V
SW
(differential) = -330 V to GND
V
SW
(differential) = +270 V to -60 V
0.3
-40° C
V
SW
(differential) = -310 V to GND
V
SW
(differential) = +250 V to -60 V
0.1
R
ON
+25° C
I
SW
= ±10 mA, ±40 mA,
R
BAT
and T
BAT
= -2 V
R
ON
-
14.5 -
Ω
+85° C 20.5 28
-40° C 10.5 -
R
ON
match
Per on-resistance test condition of
SW1, SW2.
Magnitude R
ON
SW1 - R
ON
SW2
Δ R
ON
0.15 0.8
DC current limit
+25° C
V
SW
(on) = ±10 V
I
SW
- 300 -
mA+85° C 80 160 -
-40° C - 400 425
Dynamic current limit
(t 0.5 μs)
Break switches on, all other switches
off, apply ±1 kV 10x1000 μs pulse with
appropriate protection in place.
-2.5- A
Logic input to switch output isolation
+25° C
V
SW
(T
LINE
, R
LINE
) = ±320 V, logic
inputs = GND
I
SW
-
0.1
1 μA+85° C
V
SW
(T
LINE
, R
LINE
) = ±330 V, logic
inputs = GND
0.3
-40° C
V
SW
(T
LINE
, R
LINE
) = ±310 V, logic
inputs = GND
0.1
dv/dt sensitivity - - 200 - V/μs
CPC7582
6 www.clare.com R05
1.6.2 Ringing Return Switch, SW3
Parameter Conditions Symbol Minimum Typical Maximum Unit
Off-state leakage current
+25° C
V
SW
(differential) = -320 V to GND
V
SW
(differential) = +260 V to -60 V
I
SW
-
0.1
1 μA+85° C
V
SW
(differential) = -330 V to GND
V
SW
(differential) = +270 V to -60 V
0.3
-40° C
V
SW
(differential) = -310 V to GND
V
SW
(differential) = +250 V to -60 V
0.1
R
ON
+25° C
I
SW
(on) = ±0 mA, ±10 mA R
ON
-
60 -
Ω+85° C 85 100
-40° C 45 -
DC current limit
+25° C
V
SW
(on) = ±10 V
I
SW
- 135
-
mA+85° C 70 85
-40° C
-
210
Dynamic current limit
(t 0.5 μs)
Ringing switches on, all other switches
off, apply ±1 kV 10x1000 μs pulse, with
appropriate protection in place.
2.5 A
Logic input to switch output isolation
+25° C
V
SW
(T
RINGING
, T
LINE
) = ±320 V, logic
inputs = GND
I
SW
-
0.1
1 μA+85° C
V
SW
(T
RINGING
, T
LINE
) = ±330 V, logic
inputs = GND
0.3
-40° C
V
SW
(T
RINGING
, T
LINE
) = ±310 V, logic
inputs = GND
0.1
dv/dt sensitivity - - 200 - V/μs

CPC7582MCTR

Mfr. #:
Manufacturer:
Description:
IC SWITCH LINE CARD ACC 16MLP
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union