CPC7582
R05 www.clare.com 7
1.6.3 Ringing Switch, SW4
Parameter Conditions Symbol Minimum Typical Maximum Unit
Off-state leakage current
+25° C
V
SW
(differential) = -255 V to +210 V
V
SW
(differential) = +255 V to -210 V
I
SW
-
0.05
1 μA+85° C
V
SW
(differential) = -270 V to +210 V
V
SW
(differential) = +270 V to -210 V
0.1
-40° C
V
SW
(differential) = -245 V to +210 V
V
SW
(differential) = +245 V to -210 V
0.05
On Voltage
I
SW
(on) = ± 1 mA V
SW
1.5 3 V
Ringing generator
current to ground
Ringing switches on, inputs set for
ringing mode
I
RINGING
0.1 0.25 mA
On steady-state current* Inputs set for ringing mode
I
SW
- 150 mA
Surge current*
Ringing switches on, all other switches
off, apply ±1 kV 10 x 1000 μs pulse,
with appropriate protection in place.
--2A
Release current -
I
RINGING
300 - μA
R
ON
I
SW
(on) = ±70 mA, ±80 mA R
ON
10 15 Ω
Logic input to switch output isolation
+25° C
V
SW
(R
RINGING
, R
LINE
) = ±320 V, logic
inputs = gnd
I
SW
-
0.1
1 μA+85° C
V
SW
(R
RINGING
, R
LINE
) = ±330 V, logic
inputs = gnd
0.3
-40° C
V
SW
(R
RINGING
, R
LINE
) = ±310 V, logic
inputs = gnd
0.1
dv/dt sensitivity - - 200 - V/μs
*Secondary protection and ringing source current limiting must prevent exceeding this parameter.
CPC7582
8 www.clare.com R05
1.6.4 Test Switches, SW5 and SW6
Parameter Conditions Symbol Minimum Typical Maximum Unit
Off-state leakage current
+25° C
V
SW
(differential) = -320 V to GND
V
SW
(differential) = +260 V to -60 V
I
SW
-
0.1
1 μA+85° C
V
SW
(differential) = -330 V to GND
V
SW
(differential) = +270 V to -60 V
0.3
-40° C
V
SW
(differential) = -310 V to GND
V
SW
(differential) = +250 V to -60 V
0.1
R
ON
+25° C
I
SW(ON)
= ±10 mA, ±40 mA,
T
BAT
= -2 V
R
ON
-
38 -
Ω+85° C 46 70
-40° C 28 -
DC current limit
+25° C
V
SW
(on) = ±10 V
I
SW
- 175 -
mA+85° C 80 110 -
-40° C - 210 250
Dynamic current limit
(t 0.5 μs)
Test switches on, all other switches off,
apply ±1 kV at 10x1000 μs pulse, with
appropriate protection in place.
-2.5- A
Logic input to switch output isolation
+25° C
V
SW
(T
TEST
, T
LINE
) = ±320 V,
logic inputs = gnd
I
SW
-
0.1
1 μA+85° C
V
SW
(T
TEST
, T
LINE
) = ±330 V,
logic inputs = gnd
0.3
-40° C
V
SW
(T
TEST
, T
LINE
) = ±310 V,
logic inputs = gnd
0.1
CPC7582
R05 www.clare.com 9
1.7 Additional Electrical Characteristics
Parameter Conditions Symbol Minimum Typical Maximum Unit
Digital input characteristics
Input low voltage -
V
IL
--1.5
V
Input high voltage -
V
IH
3.5 - -
Input leakage current
(high)
V
DD
= 5.5 V, V
BAT
= -75 V, V
IH
= 5 V I
IH
-0.11
μA
Input leakage current
(low)
V
DD
= 5.5 V, V
BAT
= -75 V, V
IL
= 0 V I
IL
-0.11
Voltage Requirements
V
DD
-
V
DD
4.5 5.0 5.5 V
V
BAT
1
-
V
BAT
-19 -48 -72 V
1
V
BAT
is used only for internal protection circuitry. If V
BAT
goes more positive than -10 V, the device will enter the all-off state and will remain in the all-off state until
the battery goes more negative than -15 V
Power requirements
Power consumption in
talk and all-off states
V
DD
= 5 V, V
BAT
= -48 V, measure I
DD
and I
BAT
P
-5.510
mW
Power consumption in
all other states
6.5 10
V
DD
current in talk and
all-off states
V
DD
= 5 V, V
BAT
= -48 V
I
DD
-1.12.0
mA
V
DD
current in all other
states
I
DD
-1.32.0
V
BAT
current in any state V
DD
= 5 V, V
BAT
= -48 V I
BAT
-0.110μA
Temperature Shutdown Requirements (temperature shutdown flag is active low)
Shutdown activation
temperature
Not production tested - limits are
guaranteed by design and Quality
Control sampling audits.
T
TSD_on
110 125 150 °C
Shutdown circuit
hysteresis
T
TSD_off
10 - 25 °C