NCV8509 Series
http://onsemi.com
2
MAXIMUM RATINGS
Rating Value Unit
V
IN1
(dc) −0.3 to 50 V
V
IN1
Peak Transient Voltage 50 V
V
IN2
(dc) 50 V
V
IN2
(Current out of pin) 10 mA
Operating Voltage 50 V
Input Voltage Range (SLEW, RESET, Delay) −0.3 to 10 V
V
OUT1
10 V
V
OUT2
10 V
Electrostatic Discharge (Human Body Model)
(Machine Model)
4.0
400
kV
V
Package Thermal Resistance, SOW−16 E Pad: Junction−to−Case, R
θ
JC
Junction−to−Ambient, R
θ
JA
16
57
°C/W
°C/W
Lead Temperature Soldering: Reflow: (SMD styles only) (Note 1) 240 peak (Note 2) °C
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
1. 60 second maximum above 183°C.
2. −5°C/+0°C allowable conditions.
ELECTRICAL CHARACTERISTICS (6.0 V < V
IN1
< 18 V, I
VOUT1
= 5.0 mA, I
VOUT2
= 5.0 mA, −40°C < T
J
< 125°C,
C
VOUT1
= C
VOUT2
= 10 mF; unless otherwise noted.)
Characteristic
Test Conditions Min Typ Max Unit
V
OUT1
Output Voltage
5 V Option
3.3 V Option
1.0 mA < I
VOUT1
< 100 mA
1.0 mA < I
VOUT1
< 100 mA
4.9
3.234
5.0
3.3
5.1
3.366
V
V
Dropout Voltage (V
IN1
− V
OUT1
) I
OUT
= 100 mA
I
OUT
= 100 μA
−
−
400
100
600
200
mV
mV
Load Regulation 1.0 mA < I
VOUT1
< 100 mA − 10 50 mV
Line Regulation 6.0 V < V
IN1
< 18 V − 10 50 mV
Current Limit V
OUT1
= V
OUT1
(typ) − 500 mV
V
OUT1
= 0 V
115
−
305
105
610
300
mA
mA
V
OUT2
Output Voltage
2.6 V Option
2.5 V Option
1.8 V Option
1.0 mA < I
VOUT2
< 100 mA
1.0 mA < I
VOUT2
< 100 mA
1.0 mA < I
VOUT2
< 100 mA
2.548
2.450
1.764
2.6
2.5
1.8
2.652
2.550
1.836
V
V
V
Load Regulation 1.0 mA < I
VOUT2
< 100 mA − 5.0 50 mV
Line Regulation 6.0 V < V
IN1
= V
IN2
< 18 V − 10 50 mV
Current Limit V
OUT2
= V
OUT2
(typ) − 500 mV
V
OUT2
= 0 V
105
−
305
105
610
300
mA
mA
General
Quiescent Current
I
OUT1
= I
OUT2
= 100 μA, V
IN1
= 12 V
I
OUT1
= I
OUT2
= 50 mA, V
IN1
= 14 V
−
−
125
5.0
175
10
μA
mA
Thermal Shutdown (Note 3) (Guaranteed by Design) 150 180 210 °C
3. Both outputs will turn off.