Final Datasheet Rev 1.0
July 21, 2017
Semtech
Proprietary & Confidential
Symbol Parameter Condition Min Typ Max Unit
Output Switch
I
SWX
SW1/2 Leakage V
SYS
= 42V; V
SWX
= 0, 42V; V
SYSM
= 0V -3 3 μA
IOUT
OC-00
Output Over Current Shutdown
SWx Threshold
T
J
=25°C, OC_SET = 00, Measured as V
SWX
220 mV
IOUT
OC-01
Output Over Current Shutdown
SWx Threshold
T
J
=25°C, OC_SET = 01, Measured as V
SWX
350 mV
IOUT
OC-10
Output Over Current Shutdown
SWx Threshold
T
J
=25°C, OC_SET = 10, Measured as V
SWX
460 mV
IOUT
OC-11
Output Over Current Shutdown
SWx Threshold
T
J
=25°C, OC_SET = 11, Measured as V
SWX
580 mV
IOUT
IR-00
Output Inrush Current Shutdown
SWx Threshold
T
J
=25°C, OC_SET = 00, Measured as V
SWX
930 mV
IOUT
IR-01
Output Inrush Current Shutdown
SWx Threshold
T
J
=25°C, OC_SET = 01, Measured as V
SWX
1050 mV
IOUT
IR-10
Output Inrush Current Shutdown
SWx Threshold
T
J
=25°C, OC_SET = 10, Measured as V
SWX
1150 mV
IOUT
IR-11
Output Inrush Current Shutdown
SWx Threshold
T
J
=25°C, OC_SET = 11, Measured as V
SWX
1260 mV
OC
FILT
Output Over Current Deglitch 2.75 4 7 μs
OC
IR_FILT
Output Inrush Current Deglitch 1 2 3 μs
N
IR_CYCLES
Inrush Duration 4 Cycles
T
BLANK-OC
Current Limit Blanking Time 19 25 39 μs
V
TURN-OFF
Switch Voltage for Zero Cross
Turn-Off
T
J
= 25⁰C
-37.5 37.5 mV
V
OFF-TH
Zero Cross Turn-Off Voltage
Threshold
T
J
= 25⁰C; Switch will turn off if absolute
value of voltage is below this threshold
after Zero Cross Off command
12.5 25 37.5 mV
V
CLAMP
V
SWX
Clamp Voltage
Measured as V
SW1
-V
SW2
, V
SW2
-V
SW1
I
SW
= 10mA
58 65 V
Watch Dog
WD
TO
Turn-Off Threshold
Switch shuts off if WD drops below this
voltage
500 700 900 mV
WD
RC
WD Recharge Voltage
WD recharges to this voltage when
command is received
V
GG5
-1.1 V
GG5
-0.9 V
GG5
-0.5 V
Over Temperature
T
WARN
Over Temperature Warning
(1)
90 120 °C
T
SD
Over Temperature Shutdown
(1)
120 150 °C
T
HYST
Over Temperature Hysteresis
(1)
20 °C
T
DIFF
Temperature Difference Between
Warning and Shutdown
Thresholds
(1)
30 °C
Power Transfer
F
PTO
Power Transfer Output Frequency V
SYSP
-V
SYSM
= 24V 50 80 110 kHz
R
HS_PTO
Power Transfer High Side Driver
Resistance
V
SYSP
-V
SYSM
= 24V
30 55 80 Ω
R
LS_PTO
Power Transfer Low Side Driver
Resistance
V
SYSP
-V
SYSM
= 24V 20 35 50 Ω
Notes:
(1) Not tested in production