Time Charts of SPMs Protective Function
a1 : Control supply voltage rises: After the voltage rises UV
CCR
, the circuits start to operate when next input is applied.
a2 : Normal operation: IGBT ON and carrying current.
a3 : Under voltage detection (UV
CCD
).
a4 : IGBT OFF in spite of control input condition.
a5 : Fault output operation starts.
a6 : Under voltage reset (UV
CCR
).
a7 : Normal operation: IGBT ON and carrying current.
Figure 8. Under-Voltage Protection (Low-side)
b1 : Control supply voltage rises: After the voltage reaches UV
BSR
, the circuits start to operate when next input is applied.
b2 : Normal operation: IGBT ON and carrying current.
b3 : Under voltage detection (UV
BSD
).
b4 : IGBT OFF in spite of control input condition, but there is no fault output signal.
b5 : Under voltage reset (UV
BSR
)
b6 : Normal operation: IGBT ON and carrying current
Figure 9. Under-Voltage Protection (High-side)
Input Signal
Output Current
Fault Output Signal
Control
Supply Voltage
RESET
UV
CCR
Protection
Circuit State
SET RESET
UV
CCD
a1
a3
a2
a4
a6
a5
a7
Input Signal
Output Current
Fault Output Signal
Control
Supply Voltage
RESET
UV
BSR
Protection
Circuit State
SET RESET
UV
BSD
b1
b3
b2
b4
b6
b5
High-level (no fault output)