UZK24.071

UZK24.071, UZO24.071
U-Series
BATTERY MODULE 24V, 7AH
15. PHYSICAL DIMENSIONS AND WEIGHT
Size (WxHxD) 137x186x143mm with installed sensor board UZS24.100
137x186x135mm without installed sensor board UZS24.100
Weight
6000g / 13.3lb UZK24.071
800g / 1.8lb UZO24.071
Fig. 15-1 Front view Fig. 15-2 Side view
Fig. 15-3 Isometric view
Jul. 2014 / Rev. 1.2 DS-UZK24.071-EN
All parameters are specified at, 25°C ambient temperature unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
7/9
UZK24.071, UZO24.071
U-Series
BATTERY MODULE 24V, 7AH
16. RECOMMENDATIONS FOR A LONG BATTERY LIFE
Temperature:
The temperature has the most impact on the service life. The hotter the temperature, the earlier the wear-out phase
of the battery begins. The wear-out results in a degradation of battery capacity. Place the battery module in a cool
location, E.g. near the bottom of the control cabinet. Do not place the battery module near heat generating devices.
Do not overcharge batteries!
Fig. 16-1 Service life vs. ambient temperature, typ.
20°C
10
30°C 35°C
40°C
45°C
8
6
4
2
Ambient Temperature
25°C
1
3
5
7
9
Service Life in Years
Design Life
of Battery
A:
3-5 Years
B:
6-9 Years
C:
10-12 Years
A
B
C
Number of discharge cycles and depth of discharge:
Do not discharge batteries more than necessary. Set buffer time limiter to the required buffer time. The number, as
well as the depth of discharging cycles is limited. A replacement of the battery might be necessary earlier.
When choosing the battery capacity, always try to get the next higher capacity than required. The depth of discharge
reduces the service life of the battery and limits the number of cycles.
Fig. 16-2 Battery degradation vs. discharging
cycles, typ.
0
120%
100%
40%
20%
Number of Discharging Cycles
200
60%
80%
Cell Capacity
Depth of
discharge
A:
100%
B:
50%
C:
30%
400 600 800 1000 1200
A
B
C
Store batteries fully charged
Do not store discharged batteries. Keep batteries fully charged!
Charge retention is important to get the longest battery life. Stored batteries which are not fully charged age faster
then charged batteries. Batteries which are not in use should be recharged at least once a year. The higher the
ambient temperature, the shorter the charging interval. At storage temperatures higher than 30°C, recharging should
be done at least every nine months.
Jul. 2014 / Rev. 1.2 DS-UZK24.071-EN
All parameters are specified at, 25°C ambient temperature unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
8/9
UZK24.071, UZO24.071
U-Series
BATTERY MODULE 24V, 7AH
Jul. 2014 / Rev. 1.2 DS-UZK24.071-EN
All parameters are specified at, 25°C ambient temperature unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
17. MOUNTING ORIENTATIONS
The standard mounting orientation is the vertical installation onto a flat surface.
Fig. 17-1 Standard mounting orientation
The following mounting orientations are also allowed:
Fig. 17-2 Allowed mounting orientation
Do not use the battery module in an upside down position:
Fig. 17-3 Forbidden mounting orientation