H7BR
H7BR
10
Mode Setting procedureDescriptionApplicable modelSetting item
(Display)
Mode Setting procedureDescription
H7BR-CjH7BR-Bj
Setting item
(Display)
Function
setting
mode
Prescale
value
(PS)
Yes Yes Can calculate and
display a physical
parameter (volume,
length, etc.) from the
present value. For
example, if one count
input represented a
movement of 0.02
mm, the prescale
value would be 0.02.
Values from 0.001 to
99.999 are possible.
Change the value of the digits with the corresponding
keys, 1 to 5.
12345
.....
012 8 9
Compensa-
tion count
value
(C.C)
No Yes Use compensation
input to change the
count value to set
value.
.....
012 8 9
Change the value of the digits with the corresponding
keys, 1 to 6.
Press the Code Key to change the plus or minus sign of
the set value.
(+) (blank) (-)
Ć
Key
protection
level
Yes Yes Locks certain keys to
prevent accidental
operation. The key
protection level, kP-1
to kP-4, determines
which keys are
locked when the key
protection input is
ON. The locked keys
are crossed out in
the diagram on the
right.
Sequence when changing the key protection level using
the Increment Keys (1 to 6).
<KP-1> <KP-2>
<KP-4><KP-3>
KpĆ1 KpĆ2 KpĆ3 KpĆ4
Teaching
Mode
Prescale
value
(PS)
No Yes --- By setting the conversion count value and pressing the
TEACH Key, the prescale value is automatically
calculated and set.
Set value 1
(two-stage
model only)
(SET1)
No Yes
--- By pressing the TEACH Key, the Present value is set as
the set value.
Set value 2
(SET2)
No Yes
Note: 1. Settings changed in setting mode are not effective until run mode is entered.
2. Control output is prohibited in teaching mode. Output is OFF in coincidence-ON operation and ON in coincidence-OFF operation.
3. The TEACH Key is disabled when the H7BR is turned OFF, when no teaching is possible. Other functions are enabled regardless of
whether the H7BR is turned ON or OFF.
H7BR
H7BR
11
Examples
Run Mode
Changing the Set Value
1. Press the DISPLAY Key to change the displayed preset value 1
and 2 during operation.
2. Change the set value from 250 to 1,250.
Pressing keys 1 through 6 increments the corresponding column
by1.
Non-significant zeros are normally not shown on the set value
display.
Batch Set Value Change
(Applicable to Standard Models Only)
1. Selecting Batch Count Display
Switch the count display over to batch count display.
Press the BATCH Key.
2. Batch Set Value Change
Change the batch set value while the batch count is displayed.
Pressing keys 1 through 6 increments the corresponding column by
1.
Non-significant zeros are normally not shown on the set value
display.
In order to switch the batch count display over to the count
display, press the DISPLAY Key.
Setting Mode
Changing Settings in the Function Setting Mode
1. Press the MODE Key to switch from run mode to setting mode.
The Counter will continue operation if switched from run
mode to function setting mode during operation.
The MODE Key will be locked if the key protection function is
enabled.
Settings changed in the function setting mode are not
effective until run mode is entered. As the operating
conditions will change in this case, always reset operation
with the RESET Key or a reset input.
2. Press the MODE Key to scroll successively through the items
that can be set. Release the MODE Key to select the desired
item.
H7BR
H7BR
12
3. Changing the selected item
Press the MODE Key until the desired item appears
Change the item setting by pressing keys 1 through 6. (Press
the DISPLAY Key to switch back from function setting mode
to run mode.)
Press the DISPLAY Key to return to Run mode from Setting
mode.
Teaching Mode (± Range Models Only)
Changing to Teaching Mode (Power Must be ON)
Change from run mode to teaching mode.
Press the TEACH Key.
If prescale teaching is not required, press the MODE Key and go to
Set Value 1 Teaching.
Prescale Teaching
1. Perform prescale teaching of the H7BR in teaching mode.
The prescale display shows 0.000.
2. Set 10 cm as a converted count value, for example.
Pressing keys 1 through 6 increments the corresponding column by
1.
By pressing one of keys 1 through 6, the counter PV (present
value) display indicates 0.