H7BR
H7BR
13
3. Input a count signal corresponding to the conversion count value
through the external sensor.
• The display on the right side indicates that an input of 50 counts
has been input from the external sensor with the controlled
object moved 10 cm.
4. Perform prescale value teaching per count.
Press the TEACH Key. (Prescale value 0.2 = 10 cm/50)
• If the conversion count value input at step 3 is a negative value,
the prescale value will be calculated using the absolute value of
the conversion count value.
• The fraction is rounded off for prescale calculations. (It is
rounded upward when displaying negative values.)
• While the TEACH Key is pressed, the teaching prescale value
(i.e., 0.2) is displayed.
Set Value 1 Teaching
1. Press the MODE Key to perform the teaching of set value 1,
provided that the H7BR is a two-stage model.
2. Input an appropriate count signal from the external sensor.
3. Register the count value 250 as the set value, for example.
Press the TEACH Key.
• The teaching set value is displayed while the TEACH Key is
pressed.
Set Value 2 Teaching (Two-stage Models Only)
• Perform the same procedure as Set Value 1 Teaching above.
Press the DISPLAY Key to return to run mode from teaching
mode.