8.4 Dielectric Withstanding Voltage (DWV) Adjacent Contacts:
There shall be no arc over, insulation breakdown or excessive leakage (>1 mA) when tested in
accordance with EIA-364-20 on mated connectors. See Table 7 below:
Table 5
DWV – Adjacent Contacts
Test Voltage Test Duration
(Minutes)
Points of Measurement
1000 VDC
1
Between adjacent contacts
8.5 Dielectric Withstanding Voltage (DWV) Contact to Shield:
There shall be no arc over, insulation breakdown or excessive leakage (>1 mA) when tested in
accordance with EIA-364-20 on mated connectors. See Table 8 below:
Table 6
DWV – Contact to Shield
Connector Test Voltage Test Duration
(Minutes)
Points of Measurement
All Connectors 1500 VAC
RMS
or 2121 VDC 1 Between contacts and shield
Stewart Connector
Modular Connectors with Circular Shells Product Specification PR041-01
http://www.stewartconnector.com Page 11 of 12
9.0 Mechanical Requirements
9.1 Mechanical Shock:
Mechanical Shock shall be measured in accordance with EIA-364-27, condition A, with
assembled connectors mounted rigidly to table and no discontinuities of >1 microsecond. See
Table 12 below:
Table 7
Mechanical Shock
Wave Type
Velocity
Change
(ft/s)
Number of
shocks
per direction
Duration
Each Face
(milliseconds)
Applied
Energy
(g)
Mutually
Perpendicular
Axis
Half Sine
11.3
6
11
50
3
9.2 Vibration (Sinusoidal):
Sinusoidal Vibration shall be measured in accordance with EIA-364-28 Test Condition I, with
assembled connectors mounted rigidly to vibrating table and no discontinuities of >1
microsecond. See Table 13 below:
Table 8
Sinusoidal Vibration
Wave Type Amplitude
Frequency
(Hz)
Duration
Each Face
(hours)
Mutually
Perpendicular
Axis
Sine
.06 in. DA
10 to 55
2
3
9.3 Vibration (Random):
Random Vibration shall be measured in accordance with EIA-364-28 Test Condition V Letter D,
with assembled connectors mounted rigidly to vibrating table and no discontinuities of >1
microsecond. See Table 14 below:
Table 9
Random Vibration
Frequency
(Hz)
Duration
Each Face
(minutes)
Overall
rms
(g)
Mutually
Perpendicular
Axis
50 to 2000
90
11.95
3
9.4 Durability:
Cycles (number of times) 500 mated and unmated
There to be no evidence of any damage or negative impact to form, fit or function.
Stewart Connector
Modular Connectors with Circular Shells Product Specification PR041-01
http://www.stewartconnector.com Page 12 of 12
10.0 Environmental Conditions
Note: Unless otherwise specified, all environmental testing is to be done with the connector in the mated
state.
10.1 Temperature Life:
Temperature life shall be measured in accordance with EIA-364-17, per method A. See Table 16
below:
Table 10
Temperature Life
Temperature (ºC) Duration (hours)
85±2 500
10.2 Thermal Shock:
Thermal Shock shall be measured in accordance with EIA/TIA-568. See Table 17 below:
Table 11
Thermal Shock
Temperature
(±3 ºC)
Number of
Cycles
Duration at Each
Extreme (Minutes)
Test
Condition
-
40 to +85
25
30
1
10.3 Temperature / Humidity:
Temperature / Humidity shall be measured in accordance with EIA-364-31, Method IV. See
Table 18 below:
Table 12
Temperature / Humidity
Relative
Humidity
(
±3 %)
Low
Temperature
(±2 ºC)
High
Temperature
(±2 ºC)
Cold
Sub-cycle
(±2 ºC)
Cycle
Time
(hours)
Number
Of
Cycles
93
25
65
-
10
24
21
10.4 Ingress protection:
Tested per IEC/EN 60529, section 14.2.8. Depth up to 1 meter, duration 30 minutes (IP67
versions only).

67PPC-010-K

Mfr. #:
Manufacturer:
Stewart Connector / Bel
Description:
Ethernet Cables / Networking Cables CABLE RJ45 1M PLUG CAT6 SHIELDED
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet