6.42
IDT70V9089/79S/L
High Speed 3.3V 64/32K x 8 Synchronous Dual-Port Static RAM Industrial and Commercial Temperature Ranges
7
AC Test Conditions
Figure 1. AC Output Test load.
Figure 2. Output Test Load
(For t
CKLZ, tCKHZ, tOLZ, and tOHZ).
*Including scope and jig.
Figure 3. Typical Output Derating (Lumped Capacitive Load).
3750 drw 04
590Ω
30pF
435Ω
3.3V
DATA
OUT
590Ω
5pF*
435Ω
3.3V
DATA
OUT
3750 drw 03
Input Pulse Levels
Input Rise/Fall Times
Input Timing Reference Levels
Output Reference Levels
Output Load
GND to 3.0V
3ns Max.
1.5V
1.5V
Figures 1,2 and 3
3750 tbl 10
1
2
3
4
5
6
7
8
20 40 10060 80 120 140 160 180 200
tCD
1
,
tCD
2
(Typical, ns)
Capacitance (pF)
3750 drw 05
-1
0
10 pF is the I/O capacitance
of this device, and 30pF is the
AC Test Load Capacitance
,
6.42
IDT70V9089/79S/L
High Speed 3.3V 64/32K x 8 Synchronous Dual-Port Static RAM Industrial and Commercial Temperature Ranges
8
NOTES:
1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2).
This parameter is guaranteed by device characterization, but is not production tested.
2. The Pipelined output parameters (t
CYC2, tCD2) apply to either or both left and right ports when FT/PIPE = VIH. Flow-through parameters (tCYC1, tCD1) apply when
FT/PIPE = V
IL for that port.
3. All input signals are synchronous with respect to the clock except for the asynchronous Output Enable (OE) and FT/PIPE. FT/PIPE should be treated as a
DC signal, i.e. steady state during operation.
4. 'X' in part number indicates power rating (S or L).
AC Electrical Characteristics Over the Operating Temperature Range
(Read and Write Cycle Timing)
(3,4)
(VDD = 3.3V ± 0.3, TA = 0°C to +70°C)
70V9089/79X6
Com'l Only
70V9089/79X7
Com'l Only
70V9089/79X9
Com'l Only
Symbol Parameter Min.Max.Min.Max.Min.Max.Unit
t
CYC1
Clock Cycle Time (Flow-Through)
(2)
19
____
22
____
25
____
ns
t
CYC2
Clock Cycle Time (Pipelined)
(2)
10
____
12
____
15
____
ns
t
CH1
Clock High Time (Flow-Through)
(2)
6.5
____
7.5
____
12
____
ns
t
CL1
Clock Low Time (Flow-Through)
(2)
6.5
____
7.5
____
12
____
ns
t
CH2
Clock High Time (Pipelined)
(2)
4
____
5
____
6
____
ns
t
CL2
Clock Low Time (Pipelined)
(2)
4
____
5
____
6
____
ns
t
R
Clock Rise Time
____
3
____
3
____
3ns
t
F
Clock Fall Time
____
3
____
3
____
3ns
t
SA
Address Setup Time 3.5
____
4
____
4
____
ns
t
HA
Address Hold Time 0
____
0
____
1
____
ns
t
SC
Chip Enable Setup Time 3.5
____
4
____
4
____
ns
t
HC
Chip Enable Hold Time 0
____
0
____
1
____
ns
t
SW
R/W Setup Time 3.5
____
4
____
4
____
ns
t
HW
R/W Hold Time 0
____
0
____
1
____
ns
t
SD
Input Data Setup Time 3.5
____
4
____
4
____
ns
t
HD
Input Data Hold Time 0
____
0
____
1
____
ns
t
SAD
ADS Setup Time
3.5
____
4
____
4
____
ns
t
HAD
ADS Hold Time
0
____
0
____
1
____
ns
t
SCN
CNTEN Setup Time
3.5
____
4
____
4
____
ns
t
HCN
CNTEN Hold Time
0
____
0
____
1
____
ns
t
SRST
CNTRST Setup Time
3.5
____
4
____
4
____
ns
t
HRST
CNTRST Hold Time
0
____
0
____
1
____
ns
t
OE
Output Enable to Data Valid
____
6.5
____
7.5
____
9ns
t
OLZ
Output Enable to Output Low-Z
(1)
2
____
2
____
2
____
ns
t
OHZ
Output Enable to Output High-Z
(1)
17 17 17ns
t
CD1
Clock to Data Valid (Flow-Through)
(2)
____
15
____
18
____
20 ns
t
CD2
Clock to Data Valid (Pipelined)
(2)
____
6.5
____
7.5
____
9ns
t
DC
Data Output Hold After Clock High 2
____
2
____
2
____
ns
t
CKHZ
Clock High to Output High-Z
(1)
292929ns
t
CKLZ
Clock High to Output Low-Z
(1)
2
____
2
____
2
____
ns
Port-to-Port Delay
t
CWDD
Write Port Clock High to Read Data Delay
____
24
____
28
____
35 ns
t
CCS
Clock-to-Clock Setup Time
____
9
____
10
____
15 ns
3750 tbl 11a
6.42
IDT70V9089/79S/L
High Speed 3.3V 64/32K x 8 Synchronous Dual-Port Static RAM Industrial and Commercial Temperature Ranges
9
NOTES:
1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2).
This parameter is guaranteed by device characterization, but is not production tested.
2. The Pipelined output parameters (t
CYC2, tCD2) apply to either or both left and right ports when FT/PIPE = VIH. Flow-through parameters (tCYC1, tCD1) apply when
FT/PIPE = V
IL for that port.
3. All input signals are synchronous with respect to the clock except for the asynchronous Output Enable (OE) and FT/PIPE. FT/PIPE should be treated as a
DC signal, i.e. steady state during operation.
4. 'X' in part number indicates power rating (S or L).
AC Electrical Characteristics Over the Operating Temperature Range
(Read and Write Cycle Timing)
(3,4)
(VDD = 3.3V ± 0.3)
70V9089/79X12
Com'l & Ind
70V908979X15
Com'l Only
Symbol Parameter Min.Max.Min.Max.Unit
t
CYC1
Clock Cycle Time (Flow-Through)
(2)
30
____
35
____
ns
t
CYC2
Clock Cycle Time (Pipelined)
(2)
20
____
25
____
ns
t
CH1
Clock High Time (Flow-Through)
(2)
12
____
12
____
ns
t
CL1
Clock Low Time (Flow-Through)
(2)
12
____
12
____
ns
t
CH2
Clock High Time (Pipelined)
(2)
8
____
10
____
ns
t
CL2
Clock Low Time (Pipelined)
(2)
8
____
10
____
ns
t
R
Clock Rise Time
____
3
____
3ns
t
F
Clock Fall Time
____
3
____
3ns
t
SA
Address Setup Time 4
____
4
____
ns
t
HA
Address Hold Time 1
____
1
____
ns
t
SC
Chip Enable Setup Time 4
____
4
____
ns
t
HC
Chip Enable Hold Time 1
____
1
____
ns
t
SW
R/W Setup Time 4
____
4
____
ns
t
HW
R/W Hold Time 1
____
1
____
ns
t
SD
Input Data Setup Time 4
____
4
____
ns
t
HD
Input Data Hold Time 1
____
1
____
ns
t
SAD
ADS Setup Time
4
____
4
____
ns
t
HAD
ADS Hold Time
1
____
1
____
ns
t
SCN
CNTEN Setup Time
4
____
4
____
ns
t
HCN
CNTEN Hold Time
1
____
1
____
ns
t
SRST
CNTRST Setup Time
4
____
4
____
ns
t
HRST
CNTRST Hold Time
1
____
1
____
ns
t
OE
Output Enable to Data Valid
____
12
____
15 ns
t
OLZ
Output Enable to Output Low-Z
(1)
2
____
2
____
ns
t
OHZ
Output Enable to Output High-Z
(1)
1717ns
t
CD1
Clock to Data Valid (Flow-Through)
(2)
____
25
____
30 ns
t
CD2
Clock to Data Valid (Pipelined)
(2)
____
12
____
15 ns
t
DC
Data Output Hold After Clock High 2
____
2
____
ns
t
CKHZ
Clock High to Output High-Z
(1)
2929ns
t
CKLZ
Clock High to Output Low-Z
(1)
2
____
2
____
ns
Port-to-Port Delay
t
CWDD
Write Port Clock High to Read Data Delay
____
40
____
50 ns
t
CCS
Clock-to-Clock Setup Time
____
15
____
20 ns
3750 tbl 11b

70V9089L12PF8

Mfr. #:
Manufacturer:
IDT
Description:
SRAM 64KX8 SYNCH DUAL-PORT
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS