TISP4040H1BJR-S

AUGUST 1999 - REVISED JANUARY 2007
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Figure 4. Transformer Saturation
AI4XAO
Th1
T1
UNSATURATED L
RW
Th1
T1
SATURATED
TISP40xxH1BJ VLV Overvoltage Protector Series
APPLICATIONS INFORMATION
Transformer Protection
The inductance of a transformer winding reduces considerably when the magnetic core material saturates. Saturation occurs when the
magnetizing current through the winding inductance exceeds a certain value. It should be noted that this is a different current to the
transformed current component from primary to secondary. The standard inductance-current relationship is:
where:
L
= unsaturated inductance value in H
di
= current change in A
dt
= time period in s for current change di
E
= winding voltage in V
Rearranging this equation and working large changes to saturation gives the useful circuit relationship of:
A transformer winding volt-second value for saturation gives the designer an idea of circuit operation under overvoltage conditions. The
volt-second value is not normally quoted, but most manufacturers should provide it on request. A 50 Vµs winding will support rectangular
voltage pulses of 50 V for 1 µs, 25 V for 2 µs, 1 V for 50 µs and so on. Once the transformer saturates, primary to secondary coupling will be
lost and the winding resistance, RW, shunts the overvoltage protector, Th1 - see Figure 4. This saturated condition is a concern for long
duration impulses and a.c. fault conditions because the current capability of the winding wire may be exceeded. For example, if the on-state
voltage of the protector is 1 V and the winding resistance is 0.2 , the winding would bypass a current of 1/0.2 = 5 A, even through the
protector was in the low voltage condition.
EL
di
dt
-----
=
Ex xtLi=
(
(
Figure 5 shows a generic protection arrangement. Resistors R1 and R2, together with the overcurrent protection, prevent excessive winding
current flow under a.c. conditions. Normally these resistors would only be needed for special cases, e.g. some T1/E1 designs. Alternatively, a
split winding could be used with a single resistor connecting the windings. This resistor could be by-passed by a small capacitor to reduce
signal attenuation.
Figure 5. Transformer Winding Protection
Th1 SIGNAL
T1
OVER-
CURRENT
PROTECTION
LINE
R1
R2
AI4XAN
Overcurrent protection upstream from the overvoltage protector can be fuse, PTC or thick film resistor based. For very high frequency circuits,
fuse inductance due to spiral wound elements may need to be evaluated.
TISP
®
Device Voltage Selection
Normally, the working voltage value of the protector, V
DRM
, would be chosen to be just greater than the peak signal amplitude over the
equipment temperature range. This would give the lowest possible protection voltage, V
(BO)
. This would minimize the peak voltage applied to
the transformer winding and increase the time to core saturation.
In high frequency circuits, there are two further considerations. Low voltage protectors have a higher capacitance than high voltage protectors.
AUGUST 1999 - REVISED JANUARY 2007
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP40xxH1BJ VLV Overvoltage Protector Series
TISP
®
Device Voltage Selection (Continued)
So a higher voltage protector might be chosen specifically to reduce the protector capacitive effects on the signal.
Low energy short duration spikes will be clipped by the protector. This will extend the spike duration and the data loss time. A higher protector
voltage will reduce the data loss time. Generally, this will not be a significant factor for inter-conductor protection.
However, clipping is significant for protection to ground, where there is continuous low-level a.c. common mode induction. In some cases the
induced a.c. voltage can be over 10 V. Repetitive clipping at the induced a.c. peaks by the protector would cause severe data corruption. The
expected a.c. voltage induced should be added to the maximum signal level for setting the protector V
DRM
value.
2-Wire Digital Systems
Typical systems using a single twisted pair connection are: Integrated Services Digital Network (ISDN) and Pair Gain.
Signal level protection at the transformer winding is given by protectors Th3 and Th5. Typically these could be TISP4015H1 type devices with a
15 V voltage protection level.
Figure 6. 2-Wire System
AI4XAL
SIGNAL
TRANSFORMER COUPLED TWO-WIRE INTERFACE
DC SUPPLY
Th5
Th4
C2
T2
OVER-
CURRENT
PROTECTION
LINE
Th1
Th2
Th3
OVER-
CURRENT
PROTECTION
DC FEED
SIGNAL
C1
T1
Two line protection circuits are given; one referenced to ground using Th1 and Th2 (left) and the other inter-wire using protector Th4 (right) -
see Figure 6. For ISDN circuits compliant to ETSI ETR 080:1993, ranges 1 and 2 can be protected by the following device types: TISP4095M3,
TISP4095H3, TISP3095H3 (combines Th1 and Th2) and TISP7095H3 (combines Th1, Th2 and Th4). Ranges 4 through 5 can be protected by:
TISP4145M3, TISP4145H3, TISP3145H3 (combines Th1 and Th2) and TISP7145H3 (combines Th1, Th2 and Th4). Device surge requirement, H
or M, will be set by the overcurrent protection components and the standards complied with. Protection of just the d.c. feed to ETSI ranges is
covered in the TISP5xxxH3 data sheet.
When loop test voltages exceed the normal d.c. feed levels, higher voltage protectors need to be selected. For two terminal protectors, for
levels up to 190 V (135 V rms) the TISP4250, H3 or M3, can be used and for 210 V (150 V rms) the TISP4290, H3 or M3, can be used.
In Pair Gain systems, the protector V
DRM
is normally set by the d.c. feed value. The following series of devices have a 160 V working voltage
at 25 °C: TISP4220M3, TISP4220H3, TISP3210H3 (combines Th1 and Th2) and TISP7210H3 (combines Th1, Th2 and Th4). These devices can
be used on 150 V d.c. feed voltages down to an ambient temperature of -25 °C. Where the subscriber equipment may be exposed to POTS
(Plain Old Telephone Service) voltage levels, protector Th4 needs a higher working voltage of about 275 V. Suitable device types are:
TISP4350M3, TISP4350H3, TISP3350H3 (combines Th1 and Th2) and TISP7350H3 (combines Th1, Th2 and Th4).
The overcurrent protection for the overvoltage protector can be fuse, PTC or thick film resistor based. Its a.c. limiting capability should be less
than the ratings of the intended overvoltage protector. Equipment complying with the year 2000 international K.20, K.21 and K.45
recommendations from the ITU-T, may be required to demonstrate protection coordination with the intended primary protector. Without adding
series resistance, a simple series fuse overcurrent protection is likely to fail the equipment for this part of the recommendation.
If the d.c. feed consists of equal magnitude positive and negative voltage supplies, appropriately connected TISP5xxxH3 unidirectional
protectors could replace Th1 and Th2.
4-Wire Digital Systems
A typical system using a two twisted pair connection is the High-bit-rate Digital Subscriber Line (HDSL) and the “S” interface of ISDN.
Figure 7 shows a generic two line system. HDSL tends to have ground referenced protection at both ends of the lines (Th1, Th2, Th3 and Th4).
The ISDN “S” interface is often inside the premises and simple inter-wire protection is used at the terminating adaptor (Th7 and Th8). In all
AUGUST 1999 - REVISED JANUARY 2007
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP40xxH1BJ VLV Overvoltage Protector Series
4-Wire Digital Systems
Figure 7. 4-Wire System
AI4XAM
DC FEED
Th9
SIGNAL
Th10
SIGNAL
TRANSFORMER COUPLED FOUR-WIRE INTERFACE
Th7
Th8
T3
T4
OVER-
CURRENT
PROTECTION
OVER-
CURRENT
PROTECTION
LINE 1
LINE 2
OVER-
CURRENT
PROTECTION
OVER-
CURRENT
PROTECTION
Th5
Th6
Th1
Th2
Th3
Th4
DC SUPPLY
SIGNAL
SIGNAL
T1
T2
cases, signal protection, Th5, Th6, Th9 and Th10, can be TISP4015H1 type devices with a 15 V voltage protection level.
For an HDSL d.c. feed voltage of 180 V or less and operation down to an ambient of -25 °C, the following Th1, Th2, Th3 and Th4 protectors
are suitable: TISP4250M3 or TISP4250H3, TISP3250H3 (combines Th1 and Th2 or Th3 and Th4) and TISP7250H3 (combines Th1, Th2 and
Th7 or Th3, Th4 and Th8). Possible overcurrent protection components are covered in the 2-wire digital systems clause.
For ISDN interfaces powered with ±40 V (ETSI, ETS 300 012 1992) the following Th1, Th2, Th3 and Th4 protectors are suitable: TISP4070M3 or
TISP4070H3 or TISP4070L3, TISP3070F3 or TISP3070H3 (combines Th1 and Th2 or Th3 and Th4) and TISP7070F3 or TISP7070H3 (combines
Th1, Th2 and Th7 or Th3, Th4 and Th8). At the terminating adaptor, the Th7 and Th8 protectors do not “see” the d.c. feed voltage and should
be selected to not clip the maximum signal level. Generally, the TISP40xxH1 series will be suitable.
Internal ISDN lines are not exposed to high stress levels and the chances of a.c. power intrusion are low (ETSI EN 300 386-2 1997).
Accordingly, the equipment port protection needs are at a lower level than ports connected to outside lines.
Home Phone Networking
Using the existing house telephone wiring, home phone networking systems place the local network traffic in a high band above the POTS and
ADSL (Asymmetrical Digital Subscriber Line) spectrum. Local network rates are 1 Mbps or more. To reject noise and harmonics, an in-line
protection and 5 MHz to 10 MHz bandpass filter module is used for the equipment. These modules are available from magnetic component
manufacturers (e.g. Bel Fuse Inc.) A typical circuit for the telephone line magnetics module is shown in Figure 8. Transformer T1 isolates the
equipment from the house wiring. The isolated winding output is voltage limited by a very low-voltage protector, Th1. With a differential voltage
of about 12 V peak to peak, the TISP4015H1 could be used for Th1. After filtering, connection is made to the differential transceiver of the
processing IC.
Figure 8. Home Phone Networking Isolation/filter/protection Circuit
AI4XAP
Th1
FILTER
C1
T1
TIP
RING
PROTECTION
HRTRX+
HRTRX-
“TISP” is a trademark of Bourns, Ltd., a Bourns Company, and is Registered in U.S. Patent and Trademark Office.
“Bourns” is a registered trademark of Bourns, Inc. in the U.S. and other countries.

TISP4040H1BJR-S

Mfr. #:
Manufacturer:
Bourns
Description:
Thyristor Surge Protection Devices (TSPD) Very Low Volt Bidirectional
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union