4
Solder Reflow Temperature Profile
Regulatory Information
The HCPL-3140/HCPL-0314 have
been approved by the following
organizations:
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884
Teil 2):2003-01
(Option 060 only)
UL
Approval under UL 1577,
component recognition program
up to V
ISO
= 2500 V
rms
. File
E55361.
CSA
Approval under CSA Component
Acceptance Notice #5, File CA
88324.
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics (HCPL-3140 Option 060)
Description Symbol Characteristic Unit
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage 150 V
rms
I - IV
for rated mains voltage 300 V
rms
I - III
for rated mains voltage 600 V
rms
I-II
Climatic Classification 55/1 00/ 21
Pollution Degree (DIN VDE 0110/1.89) 2
Maximum Working Insulation Voltage V
IORM
630 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875=V
PR
, 100% Production Test with V
PR
1181 V
peak
t
m
=1 sec, Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
V
IORM
x 1.5=V
PR
, Type and Sample Test, t
m
=60 sec, V
PR
945 V
peak
Partial discharge < 5 pC
Highest Allowable Overvoltage V
IOTM
6000 V
peak
(Transient Overvoltage t
ini
= 10 sec)
Safety-limiting values - maximum values allowed in the
event of a failure.
Case Temperature T
S
175 °C
Input Current** I
S,INPUT
230 mA
Output Power** P
S, OUTPUT
600 mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
>10
9
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section IEC/EN/
DIN EN 60747-5-2 for a detailed description of Method a and Method b partial discharge test profiles.
** Refer to the following figure for dependence of P
S
and I
S
on ambient temperature.
0
TIME (SECONDS)
TEMPERATURE (°C)
200
100
50 150100 200 250
300
0
30
SEC.
50 SEC.
30
SEC.
160°C
140°C
150°C
PEAK
TEMP.
245°C
PEAK
TEMP.
240°C
PEAK
TEMP.
230°C
SOLDERING
TIME
200°C
PREHEATING TIME
150°C, 90 + 30 SEC.
2.5°C ± 0.5°C/SEC.
3°C + 1°C/0.5°C
TIGHT
TYPICAL
LOOSE
ROOM
TEMPERATURE
PREHEATING RATE 3°C + 1°C/0.5°C/SEC.
REFLOW HEATING RATE 2.5°C ± 0.5°C/SEC.
Recommended Pb-Free IR Profile
217 °C
RAMP-DOWN
6 °C/SEC. MAX.
RAMP-UP
3 °C/SEC. MAX.
150 - 200 °C
260 +0/-5 °C
t 25 °C to PEAK
60 to 150 SEC.
20-40 SEC.
TIME WITHIN 5 °C of ACTUAL
PEAK TEMPERATURE
t
p
t
s
PREHEAT
60 to 180 SEC.
t
L
T
L
T
smax
T
smin
25
T
p
TIME
TEMPERATURE
NOTES:
THE TIME FROM 25 °C to PEAK TEMPERATURE = 8 MINUTES MAX.
T
smax
= 200 °C, T
smin
= 150 °C
Note: Non-halide flux should be used.
Note: Non-halide flux should be used.
5
OUTPUT POWER P
S
, INPUT CURRENT I
S
0
0
T
S
CASE TEMPERATURE °C
200
600
400
25
800
50 75 100
200
150 175
P
S
(mW)
125
100
300
500
700
I
S
(mA)
Insulation and Safety Related Specifications
Parameter Symbol HCPL-3140 HCPL-0314 Units Conditions
Minimum External Air Gap L(101) 7.1 4.9 mm Measured from input terminals
(Clearance) to output terminals, shortest
distance through air.
Minimum External Tracking L(102) 7.4 4.8 mm Measured from input terminals
(Creepage) to output terminals, shortest
distance path along body.
Minimum Internal Plastic Gap 0.08 0.08 mm Through insulation distance
(Internal Clearance) conductor to conductor, usually
the straight line distance
thickness between the emitter
and detector.
Tracking Resistance CTI >175 >175 V DIN IEC 112/VDE 0303 Part 1
(Comparative Tracking Index)
Isolation Group IIIa IIIa Material Group (DIN VDE
0110, 1/89, Table 1)
Absolute Maximum Ratings
Parameter Symbol Min. Max. Units Note
Storage Temperature T
S
-55 125 °C
Operating Temperature T
A
-40 100 °C
Average Input Current I
F(AVG)
25 mA 1
Peak Transient Input Current (<1 µs pulse I
F(TRAN)
1.0 A
width, 300pps)
Reverse Input Voltage V
R
5V
“High” Peak Output Current I
OH(PEAK)
0.6 A 2
“Low” Peak Output Current I
OL(PEAK)
0.6 A 2
Supply Voltage V
CC
-V
EE
-0.5 35 V
Output Voltage V
O(PEAK)
-0.5 V
CC
V
Output Power Dissipation P
O
250 mW 3
Input Power Dissipation P
I
45 mW 4
Lead Solder Temperature 260°C for 10 sec., 1.6 mm below seating plane
Solder Reflow Temperature Profile See Package Outline Drawings section
6
Electrical Specifications (DC)
Over recommended operating conditions unless otherwise specified.
Test
Parameter Symbol Min. Typ. Max. Units Conditions Fig. Note
High Level Output Current I
OH
0.2 A Vo = V
CC
- 4 2 5
0.4 0.5 Vo = V
CC
-10 3 2
Low Level Output Current I
OL
0.2 0.4 A Vo = V
EE
+2.5 5 5
0.4 0.5 Vo = V
EE
+10 6 2
High Level Output Voltage V
OH
V
CC
-4 V
CC
-1.8 V Io = -100 mA 1 6,7
Low Level Output Voltage V
OL
0.4 1 V Io = 100 mA 4
High Level Supply Current I
CCH
0.7 3 mA Io = 0 mA 7,8 14
Low Level Supply Current I
CCL
1.2 3 mA Io = 0 mA
Threshold Input Current I
FLH
7 mA Io = 0 mA, 9,15
Low to High Vo>5 V
Threshold Input Voltage V
FHL
0.8 V
High to Low
Input Forward Voltage V
F
1.2 1.5 1.8 V I
F
= 10 mA 16
Temperature Coefficient of DV
F
/DT
A
–1.6 mV/°C
Input Forward Voltage
Input Reverse Breakdown BV
R
5VI
R
= 10 µA
Voltage
Input Capacitance C
IN
60 pF f = 1 MHz,
V
F
= 0 V
Recommended Operating Conditions
Parameter Symbol Min. Max. Units Note
Power Supply V
CC
-V
EE
10 30 V
Input Current (ON) I
F(ON)
812mA
Input Voltage (OFF) V
F(OFF)
-3.6 0.8 V
Operating Temperature T
A
-40 100 °C

HCPL-3140-000E

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
High Speed Optocouplers 0.4A IGBT Gate Drive
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS