Table 9. DC CHARACTERISTICS, PECL V
CC
= 3.3 V, V
EE
= 0 V (Note 2)
Symbol
Characteristic
−40°C 25°C 85°C
Unit
Min Typ Max Min Typ Max Min Typ Max
I
EE
Power Supply Current 100 125 160 110 130 170 110 135 175 mA
V
OH
Output HIGH Voltage (Note 3) 2155 2300 2405 2155 2300 2405 2155 2300 2405 mV
V
OL
Output LOW Voltage (Note 3) 1305 1520 1605 1305 1500 1605 1305 1485 1605 mV
V
IH
Input HIGH Voltage (Single−Ended)
LVPECL
LVCMOS
LVTTL
2075
2000
2000
2420
3300
3300
2075
2000
2000
2420
3300
3300
2075
2000
2000
2420
3300
3300
mV
V
IL
Input LOW Voltage (Single−Ended)
LVPECL
LVCMOS
LVTTL
1305
0
0
1675
800
800
1305
0
0
1675
800
800
1305
0
0
1675
800
800
mV
V
BB
Output Voltage Reference 1775 1875 1975 1775 1875 1975 1775 1875 1975 mV
V
CF
LVTTL Mode Input Detect Voltage
@ IV
CF
= 700 mA
1.4 1.5 1.6 1.4 1.5 1.6 1.4 1.5 1.6 V
V
EF
Reference Voltage for
ECL Mode Connection
1900 1960 2050 1875 1953 2050 1850 1945 2050 mV
V
IHCMR
Input HIGH Voltage Common Mode
Range (Differential Configuration)
(Note 4)
2.0 3.3 2.0 3.3 2.0 3.3 V
I
IH
Input HIGH Current (PECL)
IN, IN
, EN, LEN, SETMIN, SETMAX 150 150 150
mA
I
IHH
FTUNE Input High Current @ V
CC
50 87 150 50 84 150 50 82 150
mA
I
IL
Input LOW Current (PECL)
IN, IN
, EN, LEN, SETMIN, SETMAX
0.5 0.5 0.5
mA
I
ILL
FTUNE Input LOW Current @V
EE
−10 0 10 −10 0 10 −10 0 10
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
2. Input and output parameters vary 1:1 with V
CC
. V
EE
can vary +0.3 V to −0.3 V.
3. All loading with 50 W to V
CC
− 2.0 V.
4. V
IHCMR
min varies 1:1 with V
EE
, V
IHCMR
max varies 1:1 with V
CC
. The V
IHCMR
range is referenced to the most positive side of the differential