Tyco Electronics Corporation
300 Constitutional Drive
Menlo Park, CA 94025 USA
No: C-6111
Rev: G
Date: November 5, 1993
Page: 10 of 35
If this document is printed it becomes uncontrolled. Check for the latest revision.
3.6.2 Dielectric Withstanding Voltage. When connector assemblies are tested as specified in
4.5.4, there shall be no evidence of breakdown or flashover. The real leakage current
shall be 1.0 milliampere maximum.
3.6.3 Contact Resistance.
3.6.3.1 Contact Resistance at Specified Current. When connector assemblies are tested as
specified in 4.5.5.1 or 4.5.5.2, mated contacts shall meet the requirements of Table III.
Table III. Contact Resistance At Rated Current
Contact
Conductor Test Current Voltage Drop, max mV
At Room Temp At Max. Rated Temp.
Size AWG AMPS After
Initial Conditioning
After
Conditioning
20 5.0 75 90 113
22 22 5.0 90 105 135
24 3.0 66 78 99
26 2.0 58 70 87
26 24 2.0 50 59 70
26 2.0 62 74 87
28 1.5 65 77 91
3.6.3.2 Low Signal Level Contact Resistance. When connector assemblies are tested as
specified in 4.5.5.3, mated contacts shall meet the requirements of Table IV.
Table IV. Low Signal Level Contact Resistance
Contact Conductor Resistance, max, milliohms
Size AWG
Initial
After
Conditioning
22 20 15 18
22 18 21
24 22 26
26 29 35
26 24 25 30
26 31 37
28 43 51
3.6.4 Shell to Shell Conductivity (conductive finish only). When mated connectors are tested
as specified in 4.5.6, the measured voltage drop shall be as shown in Table V.
Tyco Electronics Corporation
300 Constitutional Drive
Menlo Park, CA 94025 USA
No: C-6111
Rev: G
Date: November 5, 1993
Page: 11 of 35
If this document is printed it becomes uncontrolled. Check for the latest revision.
Table V. Shell-To-Shell Conductivity
Connector Class Voltage Drop max, mV
Initial After Conditioning
Environment Resistant,
EME-Shielded
1.0
1.5
Other Classes
2.5
5.0
3.6.5 Electrical Engagement. When connector assemblies are tested as specified in 4.5.7, the
electrical engagement shall be as shown in Table VI.
Table VI. Electrical Engagement
Connector
Series
Electrical Engagement, min.
Inch (mm)
MTC50
0.030 (0.76)
MTC100
0.050 (1.27)
3.6.6 Contact Engagement and Separation Forces. When socket contacts are tested as
specified in 4.5.8, the largest value of the engagement force and the smallest value of
the separation force measured on any contact shall be as shown in Table V11. The
mean value of the engagement forces measured on the individual contacts shall be as
shown in Table VII.
Table VII. Contact Engagement And Separation Forces
Engagement Force, max. Separation Force, min.
Maximum Average Value
oz-force (N)
Maximum Value
oz-force (N)
Smallest Value
oz-force (N)
9.0 (2.5)
12.0 (3.3)
1.0 (0.28)
3.6.7 Durability. After conditioning as specified in 4.5.9, connector assemblies shall meet
the subsequent performance requirements of Table XI and shall show no evidence of
damage detrimental to performance or handling.
3.6.8 Solder Termination Tensile Strength.
3.6.8.1 Round Wire Terminations. When individual wire terminations are tested at room
temperature and at the maximum rated temperature as specified in 4.5.10.1, the tensile
load required to separate each wire from its terminal shall be in accordance with Table
VIII.
Tyco Electronics Corporation
300 Constitutional Drive
Menlo Park, CA 94025 USA
No: C-6111
Rev: G
Date: November 5, 1993
Page: 12 of 35
If this document is printed it becomes uncontrolled. Check for the latest revision.
Table VIII. Round Wire Termination Tensile Strength
Wire
Wire
Tensile Load, minimum
Type Size
AWG
Connector
Series
At Room Temp
lbf (N)
At Max. Rated Temp
lbf (N)
20 MTC100 20.0 (89) 15.0 (67)
22 12.0 (53) 10.0 (44)
Annealed 24 8.0 (36) 6.0 (27)
Copper 24 MTC50 8.0 (36) 6.0 (27)
26 5.0 (22) 4.0 (18)
High 22 MTC100 16.0 (71) 12.0 (53)
Strength 24 16.0 (71) 12.0 (53)
Copper 24 MTC50 10.0 (44) 8.0 (36)
Alloy 26 10.0 (44) 8.0 (36)
3.6.8.2 Flat Conductor Cable Terminations. When terminated inserts are tested at room
temperature and at the maximum rated temperature as specified in 4.5.10.2, the
assembly shall withstand the axial load shown in Table IX without evidence of
mechanical damage to the termination areas.
Table IX Flat Conductor Cable Tensile Strength
Axial Load per Unit Cable Width
Connector
Series
At Room Temperature
lbf/inch (kN/m)
At Max. Rated Temperature
lbf/inch (kN/m)
MTC50 50 (8.8) 15 (2.6)
MTC100 50 (8.8) 20 (3.5)
3.6.9 Insert Retention. When connector assemblies are tested as specified in 4.5.11, the
inserts shall not be damaged or dislocated from their fully seated positions. The inserts
shall retain their normal positions in the shell for at least 5 seconds at the specified
load.
3.6.10 Contact Retention. When terminated inserts are tested as specified in 4.5.12, the axial
displacement of contacts shall not exceed 0.012 inch (0.30 mm) while the load is
applied.
3.6.11 Coupling Torque. When terminated connector assemblies are tested as specified in
4.5.13, the connector halves shall become fully mated, shall meet the subsequent
performance requirements of Table XI, and shall show no evidence of damage
detrimental to performance or handling of the connectors.
3.6.12 Coupling Overtorque. When terminated connector assemblies are tested as specified in
4.5.14, there shall be no evidence of mechanical damage to shells or mating hardware.