Tyco Electronics Corporation
300 Constitutional Drive
Menlo Park, CA 94025 USA
No: C-6111
Rev: G
Date: November 5, 1993
Page: 31 of 35
If this document is printed it becomes uncontrolled. Check for the latest revision.
4.5.23.2 Salt Spray (Dynamec Tast). Terminated plugs and receptacles shall be mated and
unmated 50 cycles at a rate not to exceed 300 cycles per hour. The plug and receptacle
shall be completely separated during the demate portion of the cycle. The connectors
shall then be mated and exposed to salt fog for 452 hours in accordance with MIL-
STD-1344, Method 1001. The connectors shall then be unmated and exposed to the salt
fog for 48 hours. Suitable measures shall be taken to preclude migration of
condensation along the conductors. Following the salt fog exposure, 450 mate and
unmate cycles shall be performed.
4.5.24 Ozone Exposure (see 3.6.22). Terminated, unmated connector assemblies shall be tested
in accordance with MIL-STD-1344, Method 1007.
4.5.25 Fluid Immersion (see 3.6.23). Terminated connector assemblies shall be tested in
accordance with MIL-STD-1344, Method 1016, except that measurement of initial
mating and unmating forces is not required. The following exceptions and additional
fluids shall be incorporated into the procedure:
a. One sample shall be tested in hydraulic fluid per MIL-H-83282, using the same
procedure as for MIL-H-5606 hydraulic fluid.
b. One sample shall be tested in MIL-T-5624, Grade JP-4, using the same procedure
as for MIL-T-5624, Grade JP-5.
c. Conditioning in coolant-dielectric fluid (Coolanol) shall be at the maximum rated
temperature.
d. One sample shall be tested in mineral-based lubricating oil per MIL-L-6082,
using the same procedure as for MIL-L-7808 lubricating oil.
e. Samples shall be tested in each of the following fluids, using the same procedure
as for MIL-H-5606 hydraulic fluid, except that the connectors shall be immersed
mated: Monsanto Skydrol 500 B-4, Monsanto Skydrol LD4, Chevron Hyjet IV
f. One sample shall be tested in uncracked, unleaded gasoline ("white gas"), using
the same procedure as for MIL-G-3056 gasoline.
4.5.26 Magnetic Permeability (see 3.6.24). Terminated, unmated connector assemblies shall
be tested in accordance with MIL-STD-1344, Method 3006.
4.5.27 Solderability (see 3.6.25). Terminals shall be tested in accordance with MIL-STD-202,
Method 208.